In situ DNA amplification with magnetic primers for the electrochemical detection of food pathogens.

نویسندگان

  • A Lermo
  • S Campoy
  • J Barbé
  • S Hernández
  • S Alegret
  • M I Pividori
چکیده

A sensitive and selective genomagnetic assay for the electrochemical detection of food pathogens based on in situ DNA amplification with magnetic primers has been designed. The performance of the genomagnetic assay was firstly demonstrated for a DNA synthetic target by its double-hybridization with both a digoxigenin probe and a biotinylated capture probe, and further binding to streptavidin-modified magnetic beads. The DNA sandwiched target bound on the magnetic beads is then separated by using a magneto electrode based on graphite-epoxy composite. The electrochemical detection is finally achieved by an enzyme marker, anti-digoxigenin horseradish peroxidase (HRP). The novel strategy was used for the rapid and sensitive detection of polymerase chain reaction (PCR) amplified samples. Promising resultants were also achieved for the DNA amplification directly performed on magnetic beads by using a novel magnetic primer, i.e., the up PCR primer bound to magnetic beads. Moreover, the magneto DNA biosensing assay was able to detect changes at single nucleotide polymorphism (SNP) level, when stringent hybridization conditions were used. The reliability of the assay was tested for Salmonella spp., the most important pathogen affecting food safety.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential Use of DNA Aptamer-Magnetic Bead Separation-PCR Assay for Salmonella Detection in Food

Background: Salmonella is one of the most common food-borne pathogens that can cause illness. In this study, the sensitivity and the specificity of Aptamer-Magnetic bead Separation-Polymerase Chain Reaction (AMS-PCR) method were determined for Salmonella spp. detection. Methods: Different concentrations of Salmonella enterica were mixed with streptavidin-magnetic beads coated with biotinylated...

متن کامل

Localization of Herpes Simplex Virus Type 1 DNA in Latently Infected BALB/c Mice Neurons Using in situ Polymerase Chain Reaction

Background: Herpes simplex virus type-1 (HSV-1) establishes a lifelong latent infection in neurons following primary infection. The existence of latent HSV-1 DNA in the trigeminal ganglia of infected BALB/c mice was examined using a direct in situ PCR technique, based on Digoxigenin-11-dUTP detection system with anti-digoxigenin-peroxidase and 3,3'-diaminobenzidine (DAB) substrate. Methods: Eig...

متن کامل

Advancement in electrochemical DNA-biosensors for GMOs detection: A review

Genetically modified organisms (GMOs) are plants or animals whose genetic make-up has been transformed by recombinant DNA technology, which has new features such as resistance to herbicides, virus and insect. Recently, genetic modification of food products has increased in order to reduce world poverty and hunger and increase food production However, the impact of GMOs on the human health is a ...

متن کامل

A Reverse transcription-PCR assay for detection of type A influenza virus and differentiation of avian H7 subtype

Abstract : Avian influenza virus (AIV) infection is a major cause of influenza mortality in birds and can cause human mortality and morbidity. Although the risk of infection with avian influenza virus (AIV) is generally low for most people, the pathogenic virus can cross the species barrier and acquires the ability to infect and be transmitted among the human population; therefore the ra...

متن کامل

Electrochemical biosensing in food for pathogenic bacteria based on magnetic nanostructured transducers

A novel strategy for electrochemical biosensing of food pathogenic bacteria using nanostructured electrochemical magneto electrode is reported. In this approach, the bacteria are attached to magnetic beads by immunological reaction with specific antibody against Salmonella. Further amplification of the genetic material with a double-tagging set of primer is then performed and the amplicon captu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 22 9-10  شماره 

صفحات  -

تاریخ انتشار 2007