Calculation of mean skin temperature and changes in body heat content during paediatric anaesthesia.
نویسندگان
چکیده
Mean skin temperature and changes in body heat content were calculated in several different ways from measurements made in five children during operation. Mean skin temperatures were calculated from 162 sets of measurements using 15, 12, eight, seven and four skin sites with various formulae modified according to age. The results of other formulae were compared with age-adjusted, area-weighted 15-site mean skin temperature which was used as a reference. Changes in body heat content were calculated from Burton's equation in different ways and errors from different variables in the formula were evaluated. Mean skin temperature from 12 skin sites was within 0.5 degrees C of the 15-point reference method, and that from four sites within 1 degree C. The core temperature selected and the weighting coefficients used in calculating mean body temperature were more important sources of error in the determination of change in body heat content than was mean skin temperature.
منابع مشابه
Nomograms for calculation of heat loss.
Two nomograms are presented. The first enables the mean surface and body temperatures and the body heat content of a patient of given weight to be determined from measurements of skin temperature at three sites and of the core (rectal) temperature. The second enables the change in heat content of such a patient to be determined from the change in mean body temperature.
متن کاملReduction of heat loss in neurosurgical patients using metallized plastic sheeting.
Metallized plastic sheeting (m.p.s.) was used in 14 neurosurgical patients and changes in body heat content during surgery compared with those of 14 control patients. All patients, except three in the study group and one in the control group, lost heat by the end of the operation. There was, however, a statistically significant reduction in heat loss in the patients wrapped in m.p.s. Measuremen...
متن کاملInfluence of localized auxiliary heating on hand comfort during cold exposure.
There is a need for a hand-heating system that will keep the hands warm during cold exposure without hampering finger dexterity. The purpose of this study was to examine the effects of torso heating on the vasodilative responses and comfort levels of cooled extremities during a 3-h exposure to -15 degreesC air. Subjects were insulated, but their upper extremities were left exposed to the cold a...
متن کاملEfficacy of intraoperative heat administration by ventilation with warm humidified gases and an oesophageal warming system.
We measured changes in body temperature in 12 hypothermic (mean aural temperature 34.4 (SD 1.0) degrees C) pigs during general anaesthesia with an open abdominal cavity and the effect of two warming systems: heating of inspired gases to 39 degrees C (intratracheal temperature) and oesophageal warming to 39 degrees C by a water perfused oesophageal heat exchanger. Each animal underwent both trea...
متن کاملThermoregulatory Mechanisms of Jersey Adult Cattle and Calves Based on Different Body Sites Temperature
In this experiment six healthy adult dairy Jersey cattles and eight calves (aged 4-6 months) were selected to measure temperature of different body skin sites, rectal temperature, respiration and heart rates during summer and winter. Body sites maximum and minimum temperature in calves during summer belonged to the ear, forehead, right flank, abdomen (38.4-38.9 ˚C) and carpus (32 ˚C). This was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 72 5 شماره
صفحات -
تاریخ انتشار 1994