Design and in vitro evaluation of a real-time catheter localization system using time of flight measurements from seven 3.5 MHz single element ultrasound transducers towards abdominal aortic aneurysm procedures.
نویسندگان
چکیده
Interventional surgical instrument localization is a crucial component of minimally invasive surgery. Image guided surgery researchers are investigating devices broadly categorized as surgical localizers to provide real-time information on the instrument's 3D location and orientation only. This paper describes the implementation and in vitro evaluation of a prototype real-time nonimaging ultrasound-based catheter localizer system towards use in abdominal aortic aneurysm procedures. The catheter-tip is equipped with a single element ultrasound transducer which is tracked with an array of seven external single element transducers. The performance of the system was evaluated in a water tank and additionally in the presence of pork belly tissue and also a nitinol-dacron stent graft. The mean root mean square errors were respectively 1.94±0.06, 2.54±0.31 and 3.33±0.06 mm. In addition, this paper illustrates errors induced by transducer aperture size and suggests a method for aperture error compensation. Aperture compensation applied to the same experimental data yielded mean root mean square errors of 1.05±0.07, 2.42±0.33 and 3.23±0.07mm respectively for water; water and pork; and water, pork and stent experiments. Lastly, this paper presents a video showing free-hand movement of the catheter within the water tank with data capture at 25 frames per second.
منابع مشابه
بررسی شیوع آنوریسم آئورت شکمی در افراد بالای 65 سال مراجعهکننده به مراکز سونوگرافی بیمارستانهای آموزشی شهر بیرجند در سال 1393
Background and Aim: Abdominal aortic aneurysm is an important mortality factor especially in old men. The present study aimed at investigating prevalence of abdominal aortic aneurysm in people over 65 years old who referred to the ultrasonic centers in Birjand educational hospitals in 2014. Materials and Methods: In this cross-sectional study, 1451 individuals were willingly selected from ov...
متن کاملProgress in two-dimensional arrays for real-time volumetric imaging.
The design, fabrication, and evaluation of two dimensional array transducers for real-time volumetric imaging are described. The transducers we have previously described operated at frequencies below 3 MHz and were unwieldy to the operator because of the interconnect schemes used in connecting to the transducer handle. Several new transducers have been developed using new connection technology....
متن کاملManagement of anesthesia in a patient with ruptured abdominal aortic aneurysm: A case report
Introduction: Abdominal aortic aneurysm is a multifactorial condition which associated with aging and atherosclerosis. During aneurysm surgery, hypotension after aortic clamp removing occure commonly that require specific treatments. This case report showes administration of blood and hemodynamic control methods after aortic unclumping during aortic aneurysm surgery. Patient: A 75–years-o...
متن کاملEvaluation of an Ultrasonic Insulin Delivery System in Hyperglycemic Rabbits
Introduction: Sonophoresis has been assessed as a novel approach to create skin permeability and drug delivery using low frequencies of ultrasound waves in the range of 20 kHz to 3 MHz. In this study, a system including seven 40 kHz piezoelectric transducers and an insulin chamber designed by the Medical Physics Research Center has been evaluated on hyperglycemic rabbits. Materials and Methods:...
متن کاملProgress in ring array transducers for real-time 3D ultrasound guidance of cardiac interventional devices.
As a treatment for aortic stenosis, several companies have recently introduced prosthetic heart valves designed to be deployed through a catheter using an intravenous or transapical approach. This procedure can either take the place of open heart surgery with some ofthe devices or delay it with others. Real-time 3D ultrasound could enable continuous monitoring of these structures before, during...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasonics
دوره 51 6 شماره
صفحات -
تاریخ انتشار 2011