Impacts of Intraoperative Flow on Graft Patency of Sequential and Individual Saphenous Vein Grafts
نویسندگان
چکیده
OBJECTIVE We sought to delineate the predictor of saphenous vein graft (SVG) failure and to evaluate the impact of sequential grafting of SVG on graft flow as the significant predictor of patency. METHODS Angiograms and clinical records of 439 patients who underwent coronary artery bypass grafting with aortocoronary SVG were reviewed. Of these, 708 distal anastomoses were created by 480 SVGs. Of 349 patients who underwent isolated coronary artery bypass grafting, operation was performed with an off-pump technique in 347 patients (99%). For 90 patients, a combined procedure on cardiopulmonary bypass was performed. A postoperative angiography was performed in 230 SVGs for clinical reasons. Insufficient flow (IF) was defined as a graft flow of 20 mL/min or less, measured by transit-time Doppler flowmetry during operation. RESULTS In 480 SVGs, 44 (9.2%) presented IF, and 24 SVGs presented partial or total occlusion. Six of the nine failed individual SVG had IF, whereas none of the failed sequential SVG was associated with IF. Univariate and multivariate logistic regression analyses demonstrated that IF (P = 0.002; odds ratio, 6.63) and sequential grafting (P = 0.004; odds ratio, 2.51) were significantly correlated with a failure of the SVG. The patency rate of sequential SVG to the most distal target was 78/93 (83.9%), which was significantly lower than 9/139 (93.5%) of the individual SVG (P = 0.02) and 7/113 (93.8%) of the sequential SVG to proximal targets (P = 0.02). CONCLUSIONS When both targets seem to have sufficient demand, avoidance of sequential grafting would be reasonable. Moreover, the important target should be grafted by individual grafting or sequential proximal anastomosis.
منابع مشابه
Long-term patency of sequential and individual saphenous vein coronary bypass grafts.
OBJECTIVES The long-term patency rates for individual and sequential saphenous vein grafts (SVG) as coronary bypass conduits are angiographically compared; the impact of native coronary vessel characteristics is investigated. METHODS A total of 875 distal coronary anastomoses on 500 SVGs were assessed in 430 patients at an average of 5.8+/-3 years after a coronary revascularization procedure....
متن کاملOne-year patency control and risk analysis of eSVS®-mesh-supported coronary saphenous vein grafts
BACKGROUND The eSVS® external venous nitinol mesh (Kips Bay Medical, Minneapolis, USA) was designed to improve long-term patency of coronary saphenous vein grafts (SVG) by preventing pressure-induced wall stress and reactive neo-intimal hyperplasia. We present one-year-patency rates of meshed SVGs assessed by coronary computed tomographic angiography (cCTA). PATIENTS AND METHODS Data from con...
متن کاملRoutine intraoperative angiography improves the early patency of coronary grafts performed on the beating heart.
OBJECTIVES The techniques of performing coronary revascularization without cardiopulmonary bypass are rapidly evolving. However, concern remains regarding the accuracy of coronary artery anastomoses performed on the beating heart. This report reviews the use of intraoperative angiography in the critical appraisal of "off-pump" coronary artery bypass graft (CABG) surgery. PATIENTS Intraoperati...
متن کاملThirty-year patency of a coronary sequential venous bypass graft.
BACKGROUND The optimal conduit of second choice in surgical coronary revascularization remains a matter of debate. Radial artery grafts are believed to have a better patency rate than the saphenous vein grafts, although no conclusive results have been reported. This report describes the late result of a coronary revascularization with sequential venous bypass performed 30 years earlier. METHO...
متن کاملCABG late angiographic grafting patency analysis in patients with recurrent symptoms.
OBJECTIVE Left internal thoracic artery (LITA) grafting has become the gold standard in coronary artery bypass graft procedure (CABG). In order to optimize the use of LITA or other grats, sequential anastomosis has been used. There is no consensus on equivalence of results between isolated and sequential grafts. The aim of this study is to compare the patency of isolated versus sequential graft...
متن کامل