Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

نویسندگان

  • Russell R. Russo
  • Matthew B. Burn
  • Sabir K. Ismaily
  • Brayden J. Gerrie
  • Shuyang Han
  • Jerry Alexander
  • Christopher Lenherr
  • Philip C. Noble
  • Joshua D. Harris
  • Patrick C. McCulloch
چکیده

BACKGROUND Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. METHODS Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. RESULTS Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. CONCLUSIONS There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between workplace ergonomics and musculoskeletal pain, range of motion and spinal deformities in employees: A case study, Kermanshah Oil Refinery

Introduction: Today, the health of human resources in organizations is considered an important arm. This study aimed to investigate the relationship between workplace ergonomics and musculoskeletal pain, joint range of motion (ROM), and spinal deformities in Kermanshah oil refinery staff. Materials and Methods: In the present descriptive-analytical study, all official employees of Kermanshah O...

متن کامل

Rock mass structural characterization via short-range digital photogrammetry

Because of the important role of rock mass structural properties on its mechanical behavior, determining the qualitative and quantitative properties of has been a subject of intense research. In this regard, numerous techniques such as scanline surveying, cell mapping, and geologic structure mapping have been proposed. However, applying such field surveying techniques for rock mass properties i...

متن کامل

The Relationship Between Muscle Strength and Range of Motion in Lower Extremity, and Balance and Risk of Falling in the Elderly

Background: The present study examined the relationship between muscle strength and range of motion in the lower extremity, and balance and risk of falling in the elderly. Methods: This cross-sectional study was conducted on healthy elderly (mean±SD age: 65.64±4.95 y) in Rasht City, Iran. The study participants were 65 healthy male elderly who met the stud inclusion criteria. They were selecte...

متن کامل

Measuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry

Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...

متن کامل

مقایسه تأثیر اضافه نمودن روش درمانی مکمل با درمان رایج فیزیوتراپی در کمردرد ناشی از استئوآرتریت در زنان

Background: Low back pain (LBP) is a one of the most common symptoms of vertebral column diseases. Spinal muscles have a outstanding role in maintaining vertebral column function in daily life. But proper function and motion of hip and knee joints also has an important role in performing smooth, fine and nonstressed movements of lumbar spin. Where as accurate and fine motions of hip and knee jo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017