Two months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea.
نویسندگان
چکیده
BACKGROUND Continuous positive airway pressure (CPAP) with fixed mask pressure is the current standard treatment for obstructive sleep apnoea (OSA). Auto-CPAP devices apply at any time the minimally required pressure to normalise breathing and may improve patient comfort and compliance. We present an open descriptive study of auto-CPAP treatment at home in patients previously managed with conventional CPAP. METHODS Fifteen patients with obstructive sleep apnoea (OSA), previously treated for at least one year with standard CPAP, were followed prospectively for a two month period on auto-CPAP. Outcome measures were both subjective evaluation by the patients and objective (polysomnographic) data obtained at one and two months of follow up. RESULTS The Epworth sleepiness score did not change significantly between baseline and follow up after one and two months and no systematic changes in CPAP related side effects were reported. Compared with the baseline polysomnographic values without treatment, a significant improvement in both respiratory and sleep parameters was observed during auto-CPAP. These results were not significantly different from those obtained with standard CPAP. A significant correlation was found between the effective CPAP pressure (Peff) and the amount of time spent below Peff during auto-CPAP treatment (r = 0.6, p = 0.01). CONCLUSION Long term auto-CPAP treatment in these patients with severe OSA appears to provide comparable efficacy to that of standard CPAP treatment.
منابع مشابه
Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy.
The influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional continuous positive airway pressure (CPAP) and auto CPAP therapy was evaluated. Thirty-three newly treated sleep apnoea hypopnoea syndrome (SAHS) patients were randomly allocated to conventional or auto-CPAP therapy. Six patients of each treatment group were class...
متن کاملAuto-adjusting versus fixed positive pressure therapy in mild to moderate obstructive sleep apnoea.
STUDY OBJECTIVES To determine if auto-adjusting positive airway pressure (APAP) would be better tolerated on the basis of delivering a lower mean pressure in patients with mild to moderate obstructive sleep apnoea syndrome (OSAS). DESIGN Patients spent 8 weeks on continuous positive airway pressure (CPAP) and 8 weeks on APAP in a randomized crossover design. SETTING Respiratory Sleep Disord...
متن کاملA prospective polysomnographic study on the evolution of complex sleep apnoea.
Complex sleep apnoea (CompSA) may be observed following continuous positive airway pressure (CPAP) treatment. In a prospective study, 675 obstructive sleep apnoea patients (mean age 55.9 yrs; 13.9% female) participated. Full-night polysomnography was performed at diagnosis, during the first night with stable CPAP and after 3 months of CPAP. 12.2% (82 out of 675 patients) had initial CompSA. 28 ...
متن کاملEvaluation of an auto-CPAP device for treatment of obstructive sleep apnoea.
BACKGROUND Auto-CPAP machines used in the treatment of obstructive sleep apnoea (OSA) are designed to vary the treatment pressure automatically in order always to apply the actually needed pressure. Consequently they should be able to achieve at least identical therapeutic effects as conventional constant pressure CPAP with a lower mean treatment pressure. The present study was designed to eval...
متن کاملContinuous positive airway pressure improves sleepiness but not calculated vascular risk in patients with minimally symptomatic obstructive sleep apnoea: the MOSAIC randomised controlled trial.
BACKGROUND Continuous positive airway pressure (CPAP) for symptomatic obstructive sleep apnoea (OSA) improves sleepiness and reduces vascular risk, but such treatment for the more prevalent, minimally symptomatic disease is contentious. METHODS This multicentre, randomised controlled, parallel, hospital-based trial across the UK and Canada, recruited 391 patients with confirmed OSA (oxygen de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 54 2 شماره
صفحات -
تاریخ انتشار 1999