BACKGROUND Noninvasive ventilation (NIV) intolerance is one reason for NIV failure. However, the characteristics, predictors, and outcomes of NIV intolerance are unclear. METHODS A prospective observational study was performed in the respiratory intensive care unit of a teaching hospital. Subjects with acute respiratory failure who used NIV were enrolled. Initially, continuous use of NIV was encouraged. However, if the subject could not tolerate NIV, it was used intermittently. NIV intolerance was defined as termination of NIV due to subject refusal to receive it because of discomfort, even after intermittent use was attempted. RESULTS A total of 961 subjects were enrolled in the study. Of these, 50 subjects (5.2%) experienced NIV intolerance after a median 2.4 h of NIV support. Age (OR = 0.98, 95% CI 0.963-0.996) and heart rate (OR = 1.02, 95% CI 1.006-1.030) measured before NIV were 2 independent risk factors of NIV intolerance. After 1-2 h of NIV, independent risk factors of NIV intolerance were heart rate (OR = 1.03, 95% CI 1.016-1.044) and breathing frequency (OR = 1.06, 95% CI 1.027-1.099). Intolerant subjects had no improvement in mean arterial pressure, heart rate, or breathing frequency after the NIV intervention. Moreover, intolerant subjects had a higher intubation rate (44.0% vs 25.8%, P = .008) and higher mortality (34.0% vs 22.4%, P = .08). The three most common complaints were that NIV worsened subjects' distress (46%), that NIV resulted in dyspnea (26%), and that the flow or pressure of NIV was too strong to bear (16%). CONCLUSIONS NIV intolerance worsened subjects' outcomes. Younger subjects with a high heart rate and breathing frequency may be more likely to experience NIV intolerance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness assessment of a guideline based protocol for ventilatory support management of COPD exacerbations in an emergency department

OBJECTIVES To investigate clinical outcomes according to ventilatory support indication in subjects with chronic obstructive pulmonary disease exacerbation in a "real-life" Emergency Department and to analyze potential predictors of successful noninvasive positive pressure ventilation. METHODS Retrospective cohort performed over an 18-month period, comparing the following patient groups with ...

متن کامل

Effect of noninvasive positive-pressure ventilation on survival in amyotrophic lateral sclerosis.

BACKGROUND Noninvasive positive-pressure ventilation may benefit patients with amyotrophic lateral sclerosis and respiratory insufficiency. OBJECTIVE To determine 1) whether patients tolerant of noninvasive positive-pressure ventilation have better survival than intolerant patients and 2) whether bulbar symptoms account for intolerance of noninvasive positive-pressure ventilation. DESIGN Ob...

متن کامل

[Leak monitoring in noninvasive ventilation].

Nasal mask ventilation has been shown to be effective, but outcomes do not always match expectations because of mouth leaks, patient-ventilator asynchrony, or decreased upper airway patency. These developments are detected when they lead ultimately to circuit leaks that lower the effectiveness of ventilation through pressure loss, poor inspiratory triggering, and prolonged inspiratory time. The...

متن کامل

The effect of sedation and/or analgesia as rescue treatment during noninvasive positive pressure ventilation in the patients with Interface intolerance after Extubation

BACKGROUND Sedation and/or analgesia can relieve the patient-ventilator asynchrony. However, whether sedation and/or analgesia can benefit the clinical outcome of the patients with interface intolerance is still unclear. METHODS A retrospective study was performed on patients with interface intolerance who received noninvasive positive pressure ventilation (NIPPV) after extubation in seven in...

متن کامل

Timing of noninvasive ventilation failure: causes, risk factors, and potential remedies

BACKGROUND Identifying the predictors of noninvasive ventilation (NIV) failure has attracted significant interest because of the strong link between failure and poor outcomes. However, very little attention has been paid to the timing of the failure. This narrative review focuses on the causes of NIV failure and risk factors and potential remedies for NIV failure, based on the timing factor. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 61 3  شماره 

صفحات  -

تاریخ انتشار 2016