An Exact Modeling of Signal Statistics in Energy-integrating X-ray Computed Tomography
نویسندگان
چکیده
Energy-integrating detection of x-ray sources is widely used by modern computed tomography (CT) scanners and has been an interesting research topic for the purpose of more accurately processing the data toward low-dose applications. While the energy-integrating detection can be described by a compound Poisson distribution, this work provides an alternative means to explicitly consider the Poisson statistics of the quanta and the energy spectrum of the x-ray generation. An exact solution for the first two orders of the compound Poisson statistics is presented. Given the energy spectrum of an x-ray source, the mean and variance of the measurement at any count-density level can be computed strictly. This solution can provide a quantitative measure on the condition under which an assumption of employing the most commonly-used independent identical distribution (i.i.d.), such as Gamma, Gaussian, etc, would be valid. A comparison study was performed to estimate the introduced errors of variance by using these substitute statistical functions to approximate the actual photon spectrum. The presented approach would further be incorporated in an adaptive noise treatment method for low-dose CT applications.
منابع مشابه
Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملShearlet-Based Adaptive Noise Reduction in CT Images
The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...
متن کامل