Characterization and correction of pressure drift in the ManoScan(™) high-resolution manometry system: In vitro and in vivo.

نویسندگان

  • K Lamvik
  • E Guiu Hernandez
  • R Jones
  • M-L Huckabee
چکیده

BACKGROUND A substantial pressure drift in high-resolution manometry (HRM) has been reported; however, fundamental questions remain regarding the origin and management of this drift. The aim of this study was to provide critical in-depth analyses of ManoScan(™) HRM drift in vitro and in vivo. METHODS A total of sixteen 15-min studies and twelve 5-h studies were performed in a water bath at 37 °C at 4.0 cm depth (2.9 mmHg) with ESO and ESO Z catheters. Six 5-h in vitro studies were performed similarly at a depth of 9.0 cm (6.6 mmHg). Eight 15-min studies and nine 8-h in vivo studies were performed with healthy participants. Two correction methods - thermal compensation (TC) and interpolated thermal compensation (ITC) - were tested. KEY RESULTS Overall pressure drift varied both between studies (p < 0.01) and within sensors (p < 0.01). Drift resulted from thermal shock, an initial pressure change at intubation, and baseline drift, a linear drift over time (R(2)  > 0.96). Contrary to previous reports, there was no correlation between drift and average (r = -0.02) or maximum pressure exposure (r = -0.05). Following data correction, ITC had the lowest median error but persisted with a maximum error of 2.5 mmHg (IQR = 3.0). CONCLUSIONS & INFERENCES The substantial drift in the ManoScan(™) HRM system is highly variable and not corrected via the standard operating instructions. ITC has superior performance but requires communication with the manufacturer to enable this option. This has a substantial impact on clinical diagnosis, utility of existing normative data, and future research of HRM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between esophageal clinical symptoms and manometry findings in patients with esophageal motility disorders: a cross-sectional study

Background: Manometry is the gold-standard diagnostic test for motility disorders in the esophagus. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The diagnostic value of particular esophageal clinical symptoms among patients suspected of esophageal m...

متن کامل

مانومتری با قدرت تفکیک بالا در افتراق اختلالات حرکتی مری

Background: High-resolution manometer (HRM) of the esophagus has become the main diagnostic test in the evaluation of esophageal motility disorders. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The first step of the Chicago classification described ...

متن کامل

Physicochemical Characterization of Altebrel™, a Proposed Etanercept Biosimilar

Background: Etanercept is prescribed for the rapid and effective treatment of chronic immune-mediated inflammatory disorders. Due to the expiration of etanercept patents and worldwide demand for comparable and more affordable substitutes, several biosimilars of etanercept have been approved in different countries and new ones are in the process of approval.Objectives: In the present study...

متن کامل

Combination of In Vivo Cryptorchid Testis and In Vitro Co- Culture System to Obtain High Purification and Proliferation of Mouse Spermatogonial Stem Cells

Background The present study was designed to evaluate the survival and proliferation of spermatogonial stem cells from cryptorchid mouse testis in co-culture system over a 3 weeks period. MaterialsAndMethods Sertoli and spermatogonial cells were isolated from bilateral cryptorchid mouse model testes. Isolated spermatogonial cells were co-cultured with Sertoli cells in minimal essential medium (...

متن کامل

Purification and characterization of antiviral protein from silkworm fecal matter

Antiviral proteins (AVP), present in silkworm fecal matter, show activity against nuclear polyhedrosis virus (NPV) in vitro and in vivo. The extract of silkworm fecal matter prepared in phosphate buffer solution of pH 7.5 was subjected to 50% solid ammonium sulfate precipitation to enrich AVP, then which was dialyzed. The dialysate was applied to the column containing silica gel-G, the column e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurogastroenterology and motility : the official journal of the European Gastrointestinal Motility Society

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2016