Two outbreaks of mixed etiology associated with central venous catheters inserted by phlebotomy in critical neonates.
نویسندگان
چکیده
Staphylococcus aureus and coagulase-negative staphylococci are the main cause of sepsis in Neonatal Intensive Care Unit (NICU). Central venous catheters (CVCs) are an important part of critical neonates' treatment and are associated with sepsis. The aim of this study was to investigate two outbreaks caused by Staphylococcus aureus and Staphylococcus epidermidis associated with CVC inserted by phlebotomy in critical neonates. The surveillance was performed from January 2001 to December 2005 at the Brazilian NICU. The genotypic analysis of oxacillin susceptible S. aureus (OSSA) and oxacillin resistant S. epidermidis (ORSE) was performed based on pulsed-field gel electrophoresis (PFGE). Staphylococcus was the most frequent pathogen (65.8%) with highest incidence of CoNS (59.9%) followed by S. aureus (40.1%). During the five years of surveillance, there were two outbreaks detected, occurred in January-February/02 and August/02 and confirmed by PFGE analysis. The predisposing factors for infection corresponding to both outbreaks were: age < or =7 days, hospitalization > or =7 days, and use of polyethylene CVC through dissection of vein (phlebotomy). This is the first relate of staphylococcal outbreaks associated with CVC inserted by phlebotomy in NICU. PFGE showed polyclonal spread of OSSA during both epidemic and endemic period, and two monoclonal outbreaks of ORSE in the same epidemic period of OSSA.
منابع مشابه
Incidence of catheter-related bloodstream infections in neonates following removal of peripherally inserted central venous catheters.
OBJECTIVES Catheter-associated bloodstream infections are a significant source of morbidity and healthcare cost in the neonatal ICU. Previous studies examining the prevalence of bloodstream infections after removal of peripherally inserted central venous catheters in neonates are equivocal. DESIGN A retrospective cohort study. PATIENTS All infants with peripherally inserted central venous c...
متن کاملFracture of a Broviac catheter in a low-birth-weight infant.
Central venous catheters are widely used in children, particularly in very-low-birth-weight infants in whom long-term access to the venous system is required. This may be achieved by using peripherally inserted central catheters or tunnelled central venous lines (eg Broviac or Hickman lines). Previous case reports of fractured central catheters in premature neonates have involved peripherally i...
متن کاملBloodstream Infection Incidence of Different Central Venous Catheters in Neonates: A Descriptive Cohort Study
Central venous catheters (CVCs) in neonates are associated with a risk of central line-associated bloodstream infections (CLABSI). Most reports on the incidence of CLABSI in neonates focus on umbilical venous catheters (UVCs) and peripherally inserted central catheters (PICCs). We evaluated the incidence and risk factors for CLABSI in a cohort of neonates with femoral venous catheters (FVCs), U...
متن کاملSupraclavicular Approach to Ultrasound-Guided Brachiocephalic Vein Cannulation in Children and Neonates
The correct choice of intra vascular access in critically ill neonates should be individualized depending on the type and duration of therapy, gestational and chronological age, weight and/or size, diagnosis, clinical status, and venous system patency. Accordingly, there is an ongoing demand for optimization of catheterization. Recently, the use of ultrasound (US)-guided cannulation of the subc...
متن کامل(PCVCs) in Neonates: The HIP (Heparin Infusion for PCVC) Study the Usability of Peripherally Placed Percutaneous Central Venous Catheters A Randomized, Controlled Trial of Heparin Versus Placebo Infusion to Prolong
BACKGROUND.Mechanical and infectious complications shorten the effective duration of peripherally inserted central venous catheters. Heparin use to prevent such complications and prolong the usability of peripherally inserted central venous catheters is inconclusive. OBJECTIVE.Our goal was to evaluate the effectiveness of heparin in prolonging the usability of peripherally inserted central veno...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases
دوره 13 3 شماره
صفحات -
تاریخ انتشار 2009