Characterization of two types of silanol groups on fused-silica surfaces using evanescent-wave cavity ring-down spectroscopy.

نویسندگان

  • Hsiu-Fang Fan
  • Fuping Li
  • Richard N Zare
  • King-Chuen Lin
چکیده

Evanescent-wave cavity ring-down spectroscopy has been applied to a planar fused-silica surface covered with crystal violet (CV+) cations to characterize the silanol groups indirectly. A radiation-polarization dependence of the adsorption isotherm of CV+ at the CH3CN/silica interface is measured and fit to a two-site Langmuir equation to determine the relative populations of two different types of isolated silanol groups. CV+ binding at type I sites yields a free energy of adsorption of -29.9 +/- 0.2 kJ/mol and a saturation surface density of (7.4 +/- 0.5) x 10(12) cm(-2), whereas the values of -17.9 +/- 0.4 kJ/mol and (3.1 +/- 0.4) x 10(13) cm(-2) are obtained for the type II sites. The CV+ cations, each with a planar area of approximately 120 A2, seem to be aligned randomly while lying over the SiO- type I sites, thereby suggesting that this type of site may be surrounded by a large empty surface area (>480 A2). In contrast, the CV+ cations on a type II sites are restricted with an average angle of approximately 40 degrees tilted off the surface normal, suggesting that the CV+ cations on these sites are grouped closely together. The average tilt angle increases with increasing concentration of crystal violet so that CV+ cations may be separated from each other to minimize the repulsion of nearby CV+ and SiOH sites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular orientation study of methylene blue at an air/fused-silica interface using evanescent-wave cavity ring-down spectroscopy.

Using evanescent-wave cavity ring-down spectroscopy (EW-CRDS), we monitored the change in the absorbance of a thin film of methylene blue (MB) at an air/fused-silica interface while varying the polarization of the incident light (600 nm). We derived the average orientation angle of the planar MB molecules with respect to the surface normal and observed that the average orientation angle decreas...

متن کامل

Effectiveness of charged noncovalent polymer coatings against protein adsorption to silica surfaces studied by evanescent-wave cavity ring-down spectroscopy and capillary electrophoresis.

Protein adsorption to silica surfaces is a notorious problem in analytical separations. Evanescent-wave cavity ring-down spectroscopy (EW-CRDS) and capillary electrophoresis (CE) were employed to investigate the capability of positively charged polymer coatings to minimize the adsorption of basic proteins. Adsorption of cytochrome c (cyt c) to silica coated with a single layer of polybrene (PB)...

متن کامل

Molecular adsorption at silica/CH3CN interface probed by using evanescent wave cavity ring-down absorption spectroscopy: determination of thermodynamic properties.

Evanescent wave cavity ring-down absorption spectroscopy is applied to measure the thermodynamic properties of the surface adsorption for neutral trans-4-[4-(dibutylamino)styryl]-1-(3-sulfopropyl) pyridinium (DP) and charged trans-4-[4-(dibutylamino)styryl]-1-methylpyridinium iodide (DMP+ I-) at the silica/CH3CN interface, where the interfacial density is determined by measurement of absorbance...

متن کامل

Evanescent-wave cavity ring-down investigation of polymer/solvent interactions.

Evanescent-wave cavity ring-down spectroscopy (EW-CRDS) is used to measure interfacial phenomena when methanol or water is placed in contact with a film of poly(dimethylsiloxane) (PDMS), which is attached to the face of a fused-silica prism that constitutes part of a ring cavity. In the first few minutes after contact, the uptake of methanol is slower than that of water, but after this initial ...

متن کامل

Liquid-phase and evanescent-wave cavity ring-down spectroscopy in analytical chemistry.

Due to its simplicity, versatility, and straightforward interpretation into absolute concentrations, molecular absorbance detection is widely used in liquid-phase analytical chemistry. Because this method is inherently less sensitive than zero-background techniques such as fluorescence detection, alternative, more sensitive measurement principles are being explored. This review discusses one of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 79 10  شماره 

صفحات  -

تاریخ انتشار 2007