Measuring abutment/implant joint integrity with the Periotest instrument.

نویسندگان

  • M G Faulkner
  • J F Wolfaardt
  • A Chan
چکیده

Maintenance of the integrity of the abutment/implant interface is essential and is dependent on the abutment screw retaining a preload. Evaluation of this joint is usually done by manual assessment. The purpose of the current study was to determine whether the Periotest instrument could be used to evaluate abutment screw loosening. A custom-designed apparatus was constructed to measure abutment screw loosening. Abutment screws were torqued to 10, 20, 32, and 45 Ncm and then loosened. Objective assessment of screw loosening was carried out with the Periotest device. Subjective evaluation was done by 3 experienced clinicians. The Periotest was found to be more sensitive than manual detection of abutment screw loosening. With a change of 2 in the Periotest value, it was found that the tensile preload in the joint was lost. While the Periotest was more sensitive than manual evaluation, the instrument was not sensitive enough to indicate deterioration of abutment screw loosening prior to loss of tensile preload.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use and abuse of the Periotest for 2-piece implant/abutment systems.

While the Periotest continues to be used in assessing the integrity of implants, there are numerous reports of its inconsistencies. To understand more precisely what the Periotest is actually measuring, a mathematical model was developed that illustrates the effect that various geometric and clinical parameters have on the Periotest value (PTV). In addition, the model was validated with an in v...

متن کامل

Influence of abutment design on clinical status of peri-implant tissues.

OBJECTIVE To compare the clinical soft tissue responses around implant tooth-supported 3-unit bridges using tapered abutments with those using butt-joint abutments. METHODS In a split-mouth design study, 8 mm Ankylos (Dentsply Friadent, Germany) implants were placed in the second mandibular molar region of 8 adult Macaca fascicularis monkeys about 1 month after extraction of all mandibular mo...

متن کامل

The Periotest method: implant-supported framework precision of fit evaluation.

PURPOSE In this study, the Periotest instrument was used to measure the precision of fit between cast high noble-metal frameworks and the supporting implants in a patient-simulation model. Three framework conditions and three implant-location variables were used to evaluate the rigidity of the assembly as measured by the Periotest method. The framework variables were (1) one-piece castings (OPC...

متن کامل

Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study

Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...

متن کامل

Monitoring the Changes of Material Properties at Bone-Implant Interface during the Healing Process In Vivo: A Viscoelastic Investigation

The aim of this study was to monitor the changes of viscoelastic properties at bone-implant interface via resonance frequency analysis (RFA) and the Periotest device during the healing process in an experimental rabbit model. Twenty-four dental implants were inserted into the femoral condyles of rabbits. The animals were sacrificed immediately after implant installation or on day 14, 28, or 56 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 14 5  شماره 

صفحات  -

تاریخ انتشار 1999