Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography.

نویسندگان

  • Chuanmao Fan
  • Gang Yao
چکیده

An algorithm was developed to obtain depth-resolved local optical axis in birefringent samples by using conventional polarization-sensitive optical coherence tomography (PSOCT) that uses a single circularly polarized incident light. The round-trip sample Jones matrices were first constructed from the cumulative PSOCT results. An iterative method was then applied to construct the depth-resolved local Jones matrix from which the local optical axis was calculated. The proposed algorithm was validated in samples with homogeneous axis and with depth-varying optical axis. Imaging examples were shown to demonstrate the capability of this method for extracting correct local axis and revealing features not evident in other images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Depth-resolved birefringence and differential optical axis orientation measurements with fiber-based polarization-sensitive optical coherence tomography.

Conventional polarization-sensitive optical coherence tomography (PS-OCT) can provide depth-resolved Stokes parameter measurements of light reflected from turbid media. A new algorithm that takes into account changes in the optical axis is introduced to provide depth-resolved birefringence and differential optical axis orientation images by use of fiber-based PS-OCT. Quaternion, a convenient ma...

متن کامل

Polarization sensitive optical coherence tomography of melanin provides intrinsic contrast based on depolarization

Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT. In addition to imaging based on tissue reflectivity, PS-OCT also enables depth-resolved mapping of sample polarization properties such as phase-retardation, birefringent axis orientation, Stokes vectors, and degree of polarization uniformity (DOPU). In this study, PS-OCT was used to investigate the po...

متن کامل

In vivo evaluation of human skin anisotropy by polarization-sensitive optical coherence tomography

We performed an in vivo three-dimensional analysis of anisotropic changes in the dermal birefringence of mechanically deformed human skin using polarization-sensitive optical coherence tomography (PS-OCT). The papillary-dermal birefringence of the forehead increased significantly when the skin was shrunk parallel to the body axis, and decreased significantly when the skin was shrunk perpendicul...

متن کامل

Polarization-sensitive optical coherence tomography on different tissues samples for tumor discrimination

Optical coherence tomography (OCT) is now state of the art in ophthalmology. Other medical departments, such as otolaryngology, could also benefit from this imaging modality. Polarization is a property which is a benefit to conventional OCT. It can be used in particular to detect birefringent tissue layers. To evaluate possible OCT applications in Ear, Nose and Throat (ENT) department, a fiber-...

متن کامل

Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers.

A novel polarization-sensitive optical coherence tomography (PS-OCT) system was developed using polarization maintaining (PM) optical fibers and fiber coupler to measure birefringence properties of samples. Polarization distortion due to PM fibers and coupler can be calibrated with different polarization states during two consecutive A-scans. By processing the analytical interference fringe sig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 17 11  شماره 

صفحات  -

تاریخ انتشار 2012