Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjects.
نویسندگان
چکیده
We wanted to evaluate whether lung deposition of budesonide and terbutaline sulphate differs, and to determine lung deposition of budesonide inhaled at different peak inspiratory flows, through Turbuhaler. Lung deposition of budesonide, a lipophilic substance, and of terbutaline sulphate, a hydrophilic substance, was therefore compared, after administration via an inspiratory flow-driven, multi-dose, powder inhaler (Turbuhaler, Astra Draco AB) to 10 healthy volunteers. The radionuclide 99mTc was used to label drug particles, and radioactivity, indicating drug deposition, was measured using a gamma camera. Budesonide was inhaled at a normal flow of 58 l.min-1 and at a slow flow of 36 l-min-1. At the faster flow, a mean +/- SD 27.7 +/- 9.5% of the metered dose was deposited in the lung and at the slower flow 14.8 +/- 3.3% was deposited (p < 0.001). Mean lung deposition of terbutaline sulphate inhaled at 57 l.min-1 was 27.0 +/- 7.7%. We conclude that inspiratory flow has an important effect on lung deposition, but water solubility appears to have no effect.
منابع مشابه
Lung deposition of budesonide from Turbuhaler is twice that from a pressurized metered-dose inhaler (P-MDI)
Therefore, any differences in lung deposition need to be supported by clinical data to determine whether they are clinically relevant. Indeed, there are data which show no difference, in terms of improvements in lung function, between the MDI and Turbuhaler in multiple-dose studies with ipatropium bromide [3], terbutaline [4, 5] and budesonide [6] as well as single-dose and cumulative dose stud...
متن کاملLung deposition and systemic availability of fluticasone Diskus and budesonide Turbuhaler in children.
Pharmacokinetic studies can be used to measure lung dose of inhaled drugs. The aim of this study was to compare the lung deposition of budesonide (BUD) inhaled from Turbuhaler (AstraZeneca, Lund, Sweden) and fluticasone propionate (FP) inhaled from Diskus (GlaxoSmithKline, London, UK) and to assess if the study design used for pharmacokinetic studies can be simplified. Plasma levels of BUD and ...
متن کاملPatient compliance with inhaled medication: does combining beta-agonists with corticosteroids improve compliance?
Patient compliance with an inhaled corticosteroid may be greater if it is combined with a beta-agonist. This study compared compliance with an inhaled corticosteroid (budesonide), and a short-acting inhaled beta-agonist (terbutaline sulphate), and a Turbuhaler inhaler containing a combination of the two drugs. In an open, multicentre, parallel group study 102 asthmatic patients were randomly di...
متن کاملLung deposition from the Turbuhaler in children with cystic fibrosis.
Drug delivery to patients using dry powder inhalers, such as the Turbuhaler, is believed to be influenced by the inspiratory flow used. Clinical studies have indicated that this delivery system can be used effectively by children. However, it is not known how the total and weight-corrected dose delivered to the airways varies with age. A deposition study using technetium-99m (99mTc)-labelled bu...
متن کاملScintigraphic comparison of budesonide deposition from two dry powder inhalers.
Chlorofluorocarbons (CFCs), used in metered dose inhalers (MDIs), have been identified as being deleterious to the environment leading to a ban on their production. Dry powder inhalers (DPIs) are a widely used alternative to MDIs. One disadvantage of DPIs is that in vivo lung deposition can be influenced by the patient's inspiratory flow rate. The ASTA Medica multi-dose dry powder inhaler (AM-M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 7 1 شماره
صفحات -
تاریخ انتشار 1994