Reactive pelvic cyst following total hip arthroplasty. A case report.

نویسندگان

  • Emmanuel Thienpont
  • Hilde Vernaeve
چکیده

A 77-year-old woman presented with an intrapelvic cyst which had developed secondary to polyethylene wear of the socket after total hip arthroplasty. This reactive cyst surrounded polymethylmethacrylate cement fragments due to excessive penetration in the pelvis during the initial procedure 20 years previously. This pelvic mass was responsible for gynaecologic symptoms. The cyst was resected in a first stage. Revision hip arthroplasty is scheduled because of cup wear and progressive femoral osteolysis. Cement extrusion must be avoided during total hip arthroplasty to prevent pelvic complications, since these problems can present even several years later. Cement intrusion into the pelvis possibly opens up a pathway for polyethylene wear particles to migrate into the pelvis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

INTRODUCTION Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a t...

متن کامل

Two-Stage Treatment of a Large Pelvic Cystic Pseudotumor in a Metal-On-Metal Total Hip Arthroplasty

The authors report a case of a huge cystic pseudotumor, surrounding a failed metal-on-metal total hip arthroplasty (THA). The cyst surrounded the hip anteriorly, occupied part of the anterior portion of the thigh, and extended to the anterolateral aspect of the abdomen. The case was treated by a two-stage procedure. The first stage consisted of a percutaneous drainage of the fluid content of th...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Pelvic pseudotumor following total hip arthroplasty – case report☆☆☆

Loosening is a well-known complication of total hip arthroplasty. The accumulation of detritus resulting from mechanical wear forms inflammatory cells that have the function of phagocytizing this debris. Over the long term, these cells may give rise to a local granulomatous reaction. Here, we present a report on a case of pelvic pseudotumor subsequent to total hip arthroplasty, which is conside...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 69 3  شماره 

صفحات  -

تاریخ انتشار 2003