Improved self-calibrated spiral parallel imaging using JSENSE.
نویسندگان
چکیده
Spiral MRI has several advantages over Cartesian MRI such as faster acquisitions and reduced demand in gradient. In parallel imaging, spiral trajectories are especially of great interest due to their inherent self-calibration capabilities, which is especially useful for dynamic imaging applications such as fMRI and cardiac imaging. The existing self-calibration techniques use the central spiral data that are sampled densely in the accelerated acquisition for coil sensitivity estimation. However, the resulting sensitivities are not sufficiently accurate for SENSE reconstruction due to the data truncation. In this paper, JSENSE which has been successfully used in Cartesian trajectories is extended to spiral trajectory such that the coil sensitivities and the desired image are reconstructed jointly to improve accuracy through alternating optimization. The improved sensitivities lead to a more accurate SENSE reconstruction. The results from both phantom and in vivo data are shown to demonstrate the effectiveness of JSENSE for spiral trajectory.
منابع مشابه
Accelerating T1ρ cartilage imaging using compressed sensing with iterative locally adapted support detection and JSENSE.
PURPOSE To accelerate T1ρ quantification in cartilage imaging using combined compressed sensing with iterative locally adaptive support detection and JSENSE. METHODS To reconstruct T1ρ images from accelerated acquisition at different time of spin-lock (TSLs), we propose an approach to combine an advanced compressed sensing (CS) based reconstruction technique, LAISD (locally adaptive iterative...
متن کاملAuto-calibrated parallel spiral imaging.
This work describes an auto-calibrated method for parallel imaging with spiral trajectory. The method is a k-space approach where an interpolation kernel, accounting for coil sensitivity factors, is derived from experimental data and used to interpolate the reduced data set in parallel imaging to estimate the missing k-space data. For the case of spiral imaging, this interpolation kernel is def...
متن کاملHighly accelerated 3D dynamic contrast enhanced MRI from sparse spiral sampling using integrated partial separability model and JSENSE
Dynamic contrast enhanced MRI requires high spatial resolution for morphological information and high temporal resolution for contrast pharmacokinetics. The current techniques usually have to compromise the spatial information for the required temporal resolution. This paper presents a novel method that effectively integrates sparse sampling, parallel imaging, partial separable (PS) model, and ...
متن کاملHighly Accelerated 3d Dynamic Contrast Enhanced Mri Using Partial Separability Model and Jsense
PURPOSE: Dynamic contrast enhanced (DCE) MRI requires high spatial resolution for morphological information and high temporal resolution for contrast pharmacokinetic modeling. The current fast imaging techniques [1-5] have shown success in improving the temporal resolution of DCE-MRI. However, it is still challenging to improve both the spatial and temporal resolutions simultaneously. This abst...
متن کاملImage support reduction technique for self-calibrated partially parallel imaging
F. Huang Invivo Corporation, Gainesville, Florida, United States Introduction The signal to noise ratio (SNR) of images reconstructed by using Partially Parallel Imaging (PPI) techniques is decided by the coil geometry factor (g-factor) for a given folding factor. If the image has a reduced image support, then the coil sensitivity maps have more zeros and the factor of folding is smaller than t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical engineering & physics
دوره 31 5 شماره
صفحات -
تاریخ انتشار 2009