Bone cement grafting increases implant primary stability in circumferential cortical bone defects
نویسندگان
چکیده
PURPOSE Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortical bone. METHODS Two different circumferential defect depths (2.5 mm and 5 mm) and a control (no defect) were prepared in six bovine rib bones. Fourteen implants of the same type and size (4 mm×10 mm) were placed in each group. The thickness of the cortical bone was measured for each defect. After the implant stability quotient (ISQ) values were measured three times in four different directions, bone cement was grafted to increase the primary stability of the otherwise unstable implant. After grafting, the ISQ values were measured again. RESULTS As defect depth increased, the ISQ value decreased. In the controls, the ISQ value was 85.45±3.36 (mean±standard deviation). In circumferential 2.5-mm and 5-mm defect groups, the ISQ values were 69.42±7.06 and 57.43±6.87, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement, the ISQ values significantly increased to 73.72±8.00 and 67.88±10.09 in the 2.5-mm and 5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased to more than double that before grafting in the circumferential 5-mm defect group. The ISQ values did not significantly differ when measured in any of the four directions. CONCLUSIONS The use of bone cement remarkably increased the stability of the implant that otherwise had an insufficient level of stability at placement, which was caused by insufficient cortical bone volume.
منابع مشابه
How Much Bone Cement Is Utilized for Component Fixation in Primary Cemented Total Knee Arthroplasty?
Background: No scientific evidence exists regarding the amount of bone cement used and discarded in primarycemented Total knee arthroplasty (TKA). The aim of this study was to identify the exact amount of bone cement utilizedfor component fixation in primary TKA.Methods: In a prospective study carried out at five centers, 133 primary cemented TKAs were performed. One packof 40g Palacos bone cem...
متن کاملImpaction grafting for acetabular revision: bringing back the bone.
Impaction grafting has been widely promoted on the acetabular side by Schreurs et al,1 with associated bone grafting and a cemented cup. The objectives of impaction grafting are to: 1) transform segmental defects into cavitary defects, 2) obtain a full compaction of the graft, 3) achieve primary stability of the cup, which is anatomically located in the acetabulum, and 4) restore bone stock. Th...
متن کاملThe axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.
This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...
متن کاملA Comparative Biomechanical Analysis
J Bone Joint Surg [Br] 2009;91-B:271-7. Received 16 June 2008; Accepted after revision 26 September 2008 The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted t...
متن کاملOpen distal femur fractures treated with lateral locked implants: union, secondary bone grafting, and predictive parameters.
Nonunion and secondary reduction loss complicate open distal femur fractures with bone loss. The authors hypothesized that locking plates decrease subsequent bone grafting yet maintain alignment and immediate postfixation radiographic features predict primary union. A retrospective chart/radiographic review was performed at a Level 1 university trauma center. Thirty-four adults with 36 open AO/...
متن کامل