An evaluation of automated neonatal seizure detection methods.

نویسندگان

  • Stephen Faul
  • Geraldine Boylan
  • Sean Connolly
  • Liam Marnane
  • Gordon Lightbody
چکیده

OBJECTIVE To evaluate 3 published automated algorithms for detecting seizures in neonatal EEG. METHODS One-minute, artifact-free EEG segments consisting of either EEG seizure activity or non-seizure EEG activity were extracted from EEG recordings of 13 neonates. Three published neonatal seizure detection algorithms were tested on each EEG recording. In an attempt to obtain improved detection rates, threshold values in each algorithm were manipulated and the actual algorithms were altered. RESULTS We tested 43 data files containing seizure activity and 34 data files free from seizure activity. The best results for Gotman, Liu and Celka, respectively, were as follows: sensitivities of 62.5, 42.9 and 66.1% along with specificities of 64.0, 90.2 and 56.0%. CONCLUSIONS The levels of performance achieved by the seizure detection algorithms are not high enough for use in a clinical environment. The algorithm performance figures for our data set are considerably worse than those quoted in the original algorithm source papers. The overlap of frequency characteristics of seizure and non-seizure EEG, artifacts and natural variances in the neonatal EEG cause a great problem to the seizure detection algorithms. SIGNIFICANCE This study shows the difficulties involved in detecting seizures in neonates and the lack of a reliable detection scheme for clinical use. It is clear from this study that while each algorithm does produce some meaningful information, the information would only be usable in a reliable neonatal seizure detection process when accompanied by more complex analysis, and more advanced classifiers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in automated neonatal seizure detection

This chapter highlights the current approaches in automated neonatal seizure detection and in particular focuses on classifier based methods. Automated detection of neonatal seizures has the potential to greatly improve the outcome of patients in the neonatal intensive care unit. The electroencephalogram (EEG) is the only signal on which 100% of electrographic seizures are visible and thus is c...

متن کامل

A nonparametric feature for neonatal EEG seizure detection based on a representation of pseudo-periodicity.

Automated methods of neonatal EEG seizure detection attempt to highlight the evolving, stereotypical, pseudo-periodic, nature of EEG seizure while rejecting the nonstationary, modulated, coloured stochastic background in the presence of various EEG artefacts. An important aspect of neonatal seizure detection is, therefore, the accurate representation and detection of pseudo-periodicity in the n...

متن کامل

Phenobarbital reduces EEG amplitude and propagation of neonatal seizures but does not alter performance of automated seizure detection

OBJECTIVE Phenobarbital increases electroclinical uncoupling and our preliminary observations suggest it may also affect electrographic seizure morphology. This may alter the performance of a novel seizure detection algorithm (SDA) developed by our group. The objectives of this study were to compare the morphology of seizures before and after phenobarbital administration in neonates and to dete...

متن کامل

Clinical implementation of a neonatal seizure detection algorithm

Technologies for automated detection of neonatal seizures are gradually moving towards cot-side implementation. The aim of this paper is to present different ways to visualize the output of a neonatal seizure detection system and analyse their influence on performance in a clinical environment. Three different ways to visualize the detector output are considered: a binary output, a probabilisti...

متن کامل

Validation of an Automated Seizure Detection System on Healthy Babies - Histogram-based Energy Normalization for Montage Mismatch Compensation

Seizures in newborn babies are commonly caused by problems such as lack of oxygen, haemorrhage, meningitis, infection and strokes. The aim of an automated neonatal seizure detection system is to assist clinical staff in a neonatal intensive care unit to interpret the EEG. In this work, the automated neonatal seizure detection system is validated on a set of healthy patients and its performance ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 116 7  شماره 

صفحات  -

تاریخ انتشار 2005