Effects of anticoagulants in amino acid analysis: comparisons of heparin, EDTA, and sodium citrate in vacutainer tubes for plasma preparation.

نویسندگان

  • C K Chuang
  • S P Lin
  • Y T Lin
  • F Y Huang
چکیده

in a single run for HDL-C using these three homogeneous HDL-C reagents. Mean concentrations of HDL-C in group 1 were 508 mg/L for the direct HDL-C assay, 517 mg/L for the N-geneous TM HDL-C assay, and 531 mg/L for the EZ-HDL TM-C assay. However, mean concentrations of HDL-C in group 2 were 253 mg/L for the direct HDL-C assay, 352 mg/L for the N-geneous TM HDL-C assay, and 253 mg/L for the EZ-HDL TM-C assay. Marked differences were noted between assays in individual patients. Sugiuchi et al. (6) and Harris et al. (12) reported precisions slightly better (CV Ͻ4%) than the results we obtained for direct HDL-C assay and N-geneous TM HDL assay. This may be due to use of different analyzers or differences in the methods of calibration. The data in our study agree with Okamoto et al. (7), who reported that higher HDL-C concentrations were obtained by the direct method than by the precipitation method. Our finding of no statistically significant interference from bilirubin in any of the three homogeneous HDL-C assays agrees with the findings of Sugiuchi et al. (6) and Harris et al. (12). We found that hemoglobin produced a negative interference (Ͼ10%) with the N-geneous TM HDL-C assay but had little effect on direct HDL-C assay and EZ-HDL TM-C assay. Nauck et al. (5) reported that hemoglobin produced a positive interference (Ͼ10%) and bilirubin produced a negative interference (Ͼ10%) with a different homogeneous HDL-C assay, which uses PEG and antibodies against apo B and apo C-III (5). We found that there was a negative interference (Ͼ10%) by Intralipid ® at triglycer-ide concentrations Ͼ20 000 mg/L for the N-geneous TM HDL-C and EZ-HDL TM-C assays but not for the direct HDL-C assay. However, we found inconsistent HDL-C bias among high triglyceride concentration serum samples , suggesting that interference measurements using Intralipid may not truly represent the clinical situation. The negative bias of HDL-C concentration observed in serum of high triglyceride concentration (10 000 mg/L to 29 000 mg/L) using EZ-HDL TM-C assay was much more apparent than with the other two homogeneous HDL-C assays. Harris et al. (12) reported a positive bias for N-geneous TM assay with high triglyceride concentration (4000 mg/L to 10 000 mg/L) serum samples. We are unable to explain this discrepancy. We conclude that these three homogeneous HDL-C assays are acceptable (total error Ͻ22%) for clinical laboratory use according to NCEP performance …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum C-reactive protein in Canadian Inuit and its association with genetic variation on chromosome 1q21.

References 1. Cattaneo M. Hyperhomocysteinemia, atherosclerosis and thrombosis. Thromb Haemost 1999;81:165–76. 2. Welch GN, Loscalzo J. Homocysteine and atherothrombosis. New Engl J Med 1998;338:1042–50. 3. den Heijer M, Rosendaal FR, Blom HJ, Gerrits WB, Bos GM. Hyperhomocysteinemia and venous thrombosis: a meta-analysis. Thromb Haemost 1998; 80:874–7. 4. den Heijer M, Blom HJ, Gerrits WBJ, Ro...

متن کامل

Effect of anticoagulants and cell separation media as preanalytical determinants on zymographic analysis of plasma matrix metalloproteinases.

To the Editor: Matrix metalloproteinases (MMPs) are calcium/zinc-dependent endoproteinases involved in physiologic and pathologic processes, modulating extracellular matrix degradation (1 ). MMP-2 (EC 3.4.24.24) and MMP-9 (EC 3.4.24.35) circulating in the peripheral blood (PB) of patients with neoplasia showed contrasting results, revealing the preanalytical issue of whether the method of PB sa...

متن کامل

Stabilities of quantitative plasma culture for human immunodeficiency virus, RNA, and p24 antigen from samples collected in VACUTAINER CPT and standard VACUTAINER tubes.

We evaluated the stability of human immunodeficiency virus (HIV) load markers from blood samples collected in VACUTAINER CPT or standard VACUTAINER brand tubes using sodium heparin or sodium citrate as anticoagulants. Quantitative plasma culture and p24 antigen concentrations were determined, and HIV RNA levels in plasma were measured by both reverse transcription-PCR-enzyme-linked immunosorben...

متن کامل

The effect of EDTA, heparin and storage on the erythrocyte osmotic fragility, plasma osmolality and haematocrit of adult ostriches (Struthio camelus)

To investigate the effects of two widely used anticoagulants and storage on the in vitro osmotic fragility of erythrocytes, haematocrit (Hct) and plasma osmolality of ostriches, blood was collected by venipuncture from 8 birds (90-110 kg) into vacutainer tubes containing either EDTA (k3) or lithium heparin. The osmotic fragility of the erythrocytes was determined by measuring the release of hae...

متن کامل

Effects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma.

To define the optimal blood collection parameters for plasma human immunodeficiency virus type 1 (HIV-1) viral load testing, plasma HIV-1 RNA levels were quantitated with the NASBA HIV-1 RNA QT System from blood specimens that were collected, processed, and stored under a variety of conditions that might have affected HIV-1 RNA stability. We determined that when whole blood was processed within...

متن کامل

The effects of different anticoagulants on routine canine plasma biochemistry.

The effects of heparin, ethylenediaminetetraacetic acid (EDTA), sodium citrate and sodium fluoride/potassium oxalate on plasma biochemistry results in dogs were studied and compared with serum. Blood specimens from 10 apparently clinical healthy dogs were collected and placed in different tubes containing each anticoagulant tested. Differences in albumin, acetylcholinesterase, ionized calcium a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 5  شماره 

صفحات  -

تاریخ انتشار 1998