Modeling kV X-ray-Induced Coloration in Radiochromic Films

نویسندگان

  • Mehrdad Shahmohammadi Beni
  • Dragana Krstic
  • Dragoslav Nikezic
  • Kwan Ngok Yu
چکیده

Commercially available radiochromic films are primarily designed for clinical X-ray dosimetry. These films change color upon exposures to radiation as a result of solid-state polymerization (SSP). Built on a previous model developed for SSP upon exposures to ultraviolet (UV) radiation, a new model was developed in the present work for X-ray-induced coloration in Gafchromic EBT3 films. Monte Carlo simulations using the Monte Carlo N-Particle (MCNP) code were employed to model the transport and interaction of photons and the generated secondary electrons within the film active layer. The films were exposed to continuous-energy photon beams. The dose DE in the external radiation detector (i.e., ionization chamber) was determined and the realistic dose DA in the film active layer was then obtained using the calibration coefficient R (=DA/DE). The finite element method (FEM) was used to solve the classical steady-state Helmholtz equation using the multifrontal massively parallel sparse direct solver (MUMPS). An extensive grid independence test was carried out and the numerical stability of the present model was ensured. The reflected light intensity from the film surface was used to theoretically obtain the net reflective optical density of the film exposed to X-ray. Good agreement was obtained between the experimental and theoretical results of the net reflective optical density of the film. For X-ray doses >~600 cGy, due to the already formed densely cross-linked structure in the active layer of the EBT3 film so further bond formation was less likely, the reflected light intensity from the film surface increased at a relatively lower rate when compared to those for dose values <~600 cGy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Suitability of radiochromic films for dosimetry of low energy X‐rays

This study examined the response characteristics of three commercially available radiochromic films when exposed to low energy (50 kVp) X-rays. The aim was to evaluate the films for potential use in 2D dosimetry for a low-kV intraoperative radiotherapy (IORT) device known as the ‘Intrabeam’. Dose-response relationships were obtained for Gafchromic EBT, XR-RV2, and XR-QA film in water at several...

متن کامل

Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range

The objective of this study is to evaluate the suitability of recently introduced radiochromic film EBT3 for clinical dosimetry in the kilovoltage (kV) range. For this purpose, a kV X-ray irradiator, X RAD 320ix in the range 70 to 300 kVp, a clinical 60Co source, a 6 MV and an 18 MV X-ray clinical beam from a Varian linear accelerator were calibrated following AAPM dosimetry protocols. EBT3 fil...

متن کامل

Computed Tomography Dosimeter Utilizing a Radiochromic Film and an Optical Common-mode Rejection Characterization and calibration of the GafChromic XRCT film

Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes color upon irradiation changing from amber to dark greenish-black depending on the level of exposure. The absorption spectra of Gaf...

متن کامل

Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.

PURPOSE This work investigates the dose-response curves of GAFCHROMIC(®) EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. METHODS Monochromatic beams...

متن کامل

Experimental energy response verification of XR type T radiochromic film.

This short note investigates the energy response characteristics of a relatively new high sensitivity radiochromic film (XR type T) and compares it to other radiochromic and radiographic films and thermoluminescent dosimeters. Results show that the energy response of the new XR type T film is relatively large over the range of therapeutic energies from 50 kVp superficial x-ray treatment to 18 M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018