Rotational Alignment of Femoral Component for Minimal Medial Collateral Ligament Release in Total Knee Arthroplasty
نویسندگان
چکیده
PURPOSE We attempted to determine the degree of rotation of the femoral component to achieve an ideal rectangular flexion gap with minimal medial collateral ligament (MCL) release using a modified measured technique. MATERIALS AND METHODS Group I consisted of 60 osteoarthritis patients (72 cases) who underwent total knee arthroplasty (TKA) with minimal MCL release and Group II consisted of 48 patients without osteoarthritis (61 cases). We performed computed tomography (CT) scanning of the knee with 90 degree flexion in all of the patients and analyzed the angles between the distal femur landmarks and the tibial mechanical axis using a Picture Archiving Communication system. External rotation of the femoral component from the Whiteside line and posterior condylar line was measured in group I who underwent TKA with minimum MCL release. The variance in the mediolateral flexion gap according to the degree of rotation was also measured using an Auto-Computer Aided Design program. RESULTS The CT scans showed that the Whiteside line, posterior condylar line, and transepicondylar line was more internally rotated on average from the longitudinal axis of tibia by 4.12°, 5.54°, and 4.64°, respectively, in group I compared to group II. In group I, the femoral component was inserted with an average external rotation of 5.6° from the posterior condylar line and with an average external rotation of 2.0° from the Whiteside line with minimal MCL release. From the measurements of the femoral component size and the variance in the degree of rotation using an Auto-CAD program, it was found that the change in the mediolateral flexion gap was greater when the rotation angle was greater and it was greater when the size of femoral component was larger at the same rotation angle. CONCLUSIONS The average rotation angle of the femoral component to achieve an ideal rectangular flexion gap with minimal MCL release in TKA was an external rotation of 5.6° from the posterior condylar line and an external rotation of 2.0° from the Whiteside line. We concluded that when a femoral component is small in size, greater than average external rotation needs to be applied and when a femoral component is large in size, less than average external rotation needs to be applied.
منابع مشابه
Correction of axial and rotational alignment after medial and lateral releases during balanced gap TKA
BACKGROUND AND PURPOSE Restoration of mechanical alignment after total knee arthroplasty can be achieved with ligament releases. Several previously described sequences and results achieved with cadaver knees, with measured resection implantation techniques, may not be applied to the balanced gap technique. We investigated the peroperative effect of stepwise soft tissue releases following the "t...
متن کاملIn vivo adduction and reverse axial rotation (external) of the tibial component can be minimized.
Mechanical alignment with conventional total knee arthroplasty (TKA) instruments often requires collateral ligament releases, which result in a high prevalence of adduction and reverse axial rotation (external rotation) of the tibial component during knee flexion with a variety of component designs. We used a radiographic image-matching technique to determine the contact kinematics during stand...
متن کاملA Novel Medial Soft Tissue Release Method for Varus Deformity during Total Knee Arthroplasty: Femoral Origin Release of the Medial Collateral Ligament
INTRODUCTION Numerous methods of medial soft tissue release for severe varus deformity during total knee arthroplasty (TKA) have been reported. These include tibial stripping of the superficial medial collateral ligament (MCL), pie-crusting technique, and medial epicondylar osteotomy. However, there are inherent disadvantages in these techniques. Authors hereby present a novel quantitative meth...
متن کاملMeasuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation
OBJECTIVES Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. MATERIALS...
متن کاملCombined Rotational Alignment Change after Total Knee Arthroplasty in Different Tibial Component Designs: Implications for Optimal Tibial Component Rotational Alignment
Purpose The rotational alignment of the femoral and tibial components is closely related to the results after total knee arthroplasty (TKA). In this study, we measured the combined rotational alignment change (ΔCR) after TKA and compared the different influence of symmetric and asymmetric tibial component designs on the combined rotational alignment. Materials and Methods Eighty-four patients...
متن کامل