Breast imaging devices for nuclear medicine.

نویسنده

  • Jennifer Prekeges
چکیده

Breast cancer has long been a significant cause of morbidity and mortality. Mammography is the first-line imaging examination used to detect breast cancer; it has high sensitivity but only moderate specificity. The currently used secondary imaging modalities, sonography and MRI, cannot weed out all the false-positive lesions that mammography identifies as potentially malignant. Further, many patients do not image well on mammography, so there is a significant need for alternative imaging methods. Recently, technologies using small-field, pixelated detectors optimized for breast imaging have become available for both single-photon-emitting and positron-emitting radiopharmaceuticals. This article addresses the construction and functionality of several detector types and their application to imaging of the breast. Technical aspects of nuclear breast imaging will be discussed briefly. The article concludes with an assessment of the position of nuclear medicine imaging of the breast within the overall diagnostic scheme for breast cancer detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast cancer imaging: a new role of Tc-99m sestamibi prone scintimammography for diagnosisof breast cancer

Mammography remians the procedure of choice in screening asymptomatic women for breast cancer. However, in patients with symptoms, other types of imaging play an important role in the detection of malignancies. The high cost and lack of availability of PET and MRI largely precludes the use in this patient population. TI-201 is nbt the imaging agent of choice because of its wash-out and redistri...

متن کامل

Evaluation of a new 99mTc-Bombesin analog in differentiation of malignant from benign breast tumors

Introduction: The gastrin releasing peptide (GRP) receptor is over expressed in a variety of common human tumors. Radiolabeled bombesin analogues have exhibited high binding affinity for these receptors. The aim of this study was to assess the value of a new 99mTc-bombesin analog in the differentiation of malignant from benign breast tumors. Methods: 99mTc-bombesin scans ...

متن کامل

Dynamic lymphoscintigraphy in breast cancer patients: feasibility and added value

Introduction: Lymphoscintigraphy is imaging of the lymphatic system and has been integrated into the sentinel node mapping procedures. Lymphoscintigraphy usually encompasses early or delayed static images. However, immediate dynamic imaging of the lymphatic basins and tumors has also been used as an adjunct lymphoscintigraphy imaging. The aim of this study was ...

متن کامل

Time frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information

Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...

متن کامل

Molecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis

Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue.  Methods:PubMed, Scopus and EMBASE were searched for st...

متن کامل

Biological assessment and human absorbed dose estimation of [111In]In-DTPA-antiMUC1 as a radioimmunoconjugate for breast cancer imaging

Introduction: The aim of this study was to evaluate the human organ absorbed dose of [111In]In-DTPA-antiMUC1, as a newly developed radioimmunoconjugate. Methods: [111In]In-DTPA-antiMUC1 was prepared at optimized conditions while the radiochemical purity of the tracer was investigated using ITLC method. Biodistribution of the radiolab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2012