Current Insights Regarding Metal-On-Metal Bearings for Hip Arthroplasty "2279
نویسنده
چکیده
Modern small diameter metal-on-metal (MoM) bearings for total hip arthroplasty (THA) have been developed in the nineteen-eighties to address the problem of polyethylene wear related osteolysis. Subsequently large diameter MoM hip resurfacings (HRA) were designed for young and active patients to preserve bone and avoid dislocation. Large diameter MoM THA were originally meant as an easy femoral component-only revision solution for femoral neck fractures in HRA, but were then advocated for primary THA as well. In the last decade however, increasing numbers of revisions for adverse local tissues reactions (ALTR) to metal debris have been reported. These ALTR are due to excessive wear of the MoM bearings, usually related to malpositioning of the components leading to edge loading, or in rare cases to metal sensitivity. Besides the immunological reactions, metal particles and ions have a potential local and systemic toxicity. Wear and tribocorrosion at the taper-trunnion connections of MoM THA but also THA with polyethylene and ceramic bearings have also been recognized as a cause of ALTR with extensive tissue destruction. Despite the fact that the long-term survivorship and functional results of certain MoM HRA are excellent and better than THA in the young and active patients group, MoM bearings have become very unpopular and are likely to be replaced by bearing couples of other materials.
منابع مشابه
Metal-on-metal total hip arthroplasty: the concerns.
The metal-on-metal bearing couple is having a resurgence in clinical applications seen in total hip and hip resurfacing technologies. The most noteworthy advantage of a metal-on-metal implant is the improved wear characteristics seen in vitro on wear simulators and in vivo with retrieved implants. All bearings have disadvantages, and a metal-on-metal bearing is no exception. Concerns exist rega...
متن کاملLevels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty.
Metal-on-metal (MOM) bearings for hip arthroplasty are increasing in popularity. Concern remains, however, regarding the potential toxicological effects of the metal ions which these bearings release. The serum levels of cobalt and chromium in 22 patients who had undergone MOM resurfacing arthroplasty were compared with a matched group of 22 patients who had undergone 28 mm MOM total hip arthro...
متن کاملFatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty
This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA). After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year...
متن کاملThe Epidemiology of Total Hip Arthroplasty Bearing Surface Use in the United States
Introduction: Metal on conventional ultra-high molecular weight polyethylene (UHMWPE) bearings have produced excellent long-term results in total hip arthroplasty (THA), with 20 year survivorship of almost 80%. However, the consequences of bearing surface wear, including osteolysis and aseptic loosening, have been a leading cause of late revision THA, especially in younger, more active patients...
متن کاملMetal ion levels decrease after revision for metallosis arising from large-diameter metal-on-metal hip arthroplasty.
Concerns have been renewed regarding the possible long-term effects of elevated circulating levels of cobalt and chromium as a direct result of implantation of large femoral head diameter metal-on-metal bearings. In order to establish whether metal ion levels remain persistently elevated, we compared metal ion levels before and after revision surgery in patients with large head diameter (greate...
متن کامل