A modified suturing technique for the implantation of the apical cannula of the HeartMate II left ventricular assist device.

نویسندگان

  • Efstratios I Charitos
  • Hans-Hinrich Sievers
چکیده

The secure and haemostatic implantation of the left ventricular assist device (LVAD) apex inflow cannula can sometimes be challenging, especially in the setting of an acute myocardial infarction or significant ventricular wall thinning, when the myocardial tissue may be friable and tissue strength may be compromised. In these cases, surgical complications from this site may present a challenge. We describe a modified suturing technique for the implantation of the left ventricular apical inflow cannula of the HeartMate II LVAD that may prevent surgical complications from the inflow cannula site.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Apical pseudoaneurysm following continuous flow left ventricular assist device placement.

The HeartMate II continuous flow left ventricular assist device (LVAD) (Thoratec Inc) provides circulatory support for patients with medically refractory systolic heart failure as both a bridge to transplantation and destination therapy. Although left ventricular apical pseudoaneurysm has rarely been reported with first-generation pulsatile flow LVADs, this has not been previously reported with...

متن کامل

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

Tentacles: a novel device for exposing the heart for the insertion of left apical assist device cannulae.

BACKGROUND The implantation of ventricular assist devices is a well-established procedure for the treatment of imminent heart failure. The exact positioning of the left ventricular apical inflow cannula is crucial, because inflow restrictions might occur when the cannula is placed too close to the interventricular septum or a papillary muscle. We report a novel technique using the Tentacles 3-p...

متن کامل

Principles of HeartMate II Implantation to Avoid Pump Malposition and Migration

Proper left ventricular assist device (LVAD) insertion will help maximize LVAD flow and may reduce adverse events such as right heart failure and pump thrombosis. Although no standardized insertion technique has been universally accepted, the goals are: unobstructed inflow cannula, unobstructed outflow graft with avoidance of right ventricular compression, and prevention of pump migration. To a...

متن کامل

“Suction Event” in a Patient with a HeartMate II Left Ventricular Assist Device

Case Presentation: A 31 year old male with dilated cardiomyopathy and symptoms of New York Heart Association class IV heart failure presented for left ventricular assist device (LVAD) implantation as destination therapy. The patient was admitted to the hospital approximately one month prior with decompensation of his cardiomyopathy and associated liver failure. The patient was stabilized and wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 11 4  شماره 

صفحات  -

تاریخ انتشار 2010