Severe haemolytic anaemia after replacement of the mitral valve by a St Jude medical prosthesis.

نویسندگان

  • H Feld
  • J Roth
چکیده

Severe haemolytic anaemia developed in a 33 year old patient after the mitral valve was replaced with a St Jude medical prosthesis. This was the patient's third thoracotomy. She had already had a mitral commissurotomy and a mitral valve bioprosthesis. The patient had an E+ antibody to red blood cells as well as a paraprosthetic leak. The haemolysis became less severe once the population of E+ red cells was completely haemolysed. However, the patient continued to require transfusions to remain out of heart failure. Once the valve was replaced, the haemolysis subsided. Fulminant haemolysis after mitral valve replacement is rare. When it does occur, a paraprosthetic leak should be suspected. Other causes of haemolysis, however, must also be considered and these may contribute to the severity of haemolysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Doppler derived gradient of St. Jude mechanical prosthesis, early postoperative assessment.

OBJECTIVE To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. METHODS Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute...

متن کامل

Echocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.

The major cause of late mortality and morbidity after prosthetic valve replacement is thromboembolism. The nidus for initiation of thrombus formation has been blood metal interfaces, and a new valve--the St Jude prosthesis--has therefore been developed without any metal components. We have assessed echocardiographically in 27 patients the effects of this valve on left ventricular filling charac...

متن کامل

Enlargement of mitral valve ring in a young woman with severe prosthesis-patient mismatch.

Mechanical prosthesis is the first choice for valve replacement at the mitral position in children. Replacement of the original prosthesis because of prosthesis-patient mismatch (PPM) is almost inevitable when prostheses are implanted in small children. The impact of PPM on long-term mortality becomes significant when the effective orifice area (EOA) is severely reduced. In these cases prosthes...

متن کامل

Portico Transcatheter Implantation in a Patient with Mechanical Mitral Valve

Transcatheter aortic valves implantation (TAVI) is a valid treatment for high-risk surgical candidates with symptomatic severe aortic stenosis; the safety and effectiveness of TAVI have been demonstrated in numerous clinical studies, national registries and randomized trials. Nevertheless, from this cohort of patients have been often excluded patients with prior mitral valve surgery because con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 64 1  شماره 

صفحات  -

تاریخ انتشار 1989