Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
نویسندگان
چکیده
Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum followup of 3 months was required after the surgery. Patients were assessed for uncorrected near visual acuity (UNVA) at a fixed distance (33 cm), uncorrected intermediate visual acuity (UIVA) at 60 cm, and uncorrected distance visual acuity (UDVA). Using a subjective questionnaire, patients satisfaction, their independence from using glasses, and the perception of glare and halo phenomena were also evaluated at the last follow-up. Results. Two thousand and five hundred eyes of 1558 patients underwent cataract surgery and Tecnis ZM900 multifocal IOL implantation. Four hundred and eighty seven patients (31.3%) were men, and 1071 (68.7%) were women. The mean age of the patients was 66.17 years. A UDVA of 20/30 or better was achieved by 85% of eyes. A UNVA of J1 was achieved by 93.7% of eyes and that of J2 or better was achieved by 98%. A UIVA of J4 or better was achieved by 65% and J5 or better was achived by more than 82.8% of the eyes in the study. Glare and halos were reported as severe by only 6.1% and 2.12% of patients, respectively. Ninety seven percent reported complete spectacle independence and 88% stated that they are totally satisfied with their quality of vision and would choose to have the same lens implanted again after the first implant. Five percent of the eyes in the study needed a second procedure (enhancement) to achieve a better visual result. No patient underwent lens exchange. Conclusion. Excellent near, intermediate, and distant vision was observed in patients implanted with the Tecnis ZM900 diffractive multifocal IOL. Spectacle independence and a minimum occurrence of photic phenomena make this IOL an excellent option in patients with cataract.
منابع مشابه
Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses
Aim To better understand the phenomenon of dysphotopsia in patients implanted with multifocal intraocular lenses (IOLs). Methods Forty-five patients (aged 61.8±8.9 years) implanted bilaterally with Tecnis ZM900 (diffractive multifocal), Lentis Mplus MF30 (segmented refractive multifocal) or Softec-1 (monofocal) IOLs (each n=15) 4-6 months previously and who had achieved a good surgical outcom...
متن کاملInadvertent implantation of a reversed-optic Tecnis ZM900 multifocal intraocular lens: case report.
A 51-year-old woman with age-related cataract had an uneventful phacoemulsification and a Tecnis ZM900 multifocal intraocular lens (IOL) implantation in both eyes. During IOL implantation in the left eye, the optic was unintentionally reversed in the bag and left that way. The refraction surprise was not significant and six months postoperatively the corrected distance visual acuity in both eye...
متن کاملIntraocular Lens Multifocality Combined with the Compensation for Corneal Spherical Aberration: A New Concept of Presbyopia-Correcting Intraocular Lens
The outcomes of a prospective consecutive study aimed at evaluating the visual and refractive benefit after cataract surgery with the implantation of the aspheric diffractive multifocal intraocular lens (IOL) Tecnis ZMB00 (Abbott Medical Optics) are reported. A total of 31 eyes of 19 patients (age range, 40 to 81 years) underwent phacoemulsification surgery with implantation of this aspheric mu...
متن کاملEffect of decentration on the optical performance in multifocal intraocular lenses.
AIMS To evaluate the influence of decentration on optical performance in multifocal intraocular lenses (IOLs) using eye models. METHODS This study evaluated 4 types of multifocal IOLs (ReSTOR SA60D3, Alcon; TECNIS Multifocal ZM900, AMO; ReZoom, AMO; SFX-MV1, Hoya). The evaluations were based on measurements of the near and far modulation transfer function (MTF) and visualized actual near imag...
متن کاملA Contralateral Eye Study Comparing Apodized Diffrative and Full Diffrative Lenses: Wavefront Analysis and Distance and Near Uncorrected Visual Acuity
PURPOSE To evaluate intraindividual visual acuity, wavefront errors and modulation transfer functions in patients implanted with two diffractive multifocal intraocular lenses. METHODS This prospective study examined 40 eyes of 20 cataract patients who underwent phacoemulsification and implantation of a spherical multifocal ReSTOR intraocular lens in one eye and an aspheric Tecnis ZM900 multif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2010 شماره
صفحات -
تاریخ انتشار 2010