123-131 Roberto Di Baria.qxd:-

ثبت نشده
چکیده

There is a debate in the literature about the need for Computed Tomagraphy (CT) before removing third molars, even if positive radiographic signs are present. In few cases, the third molar is so close to the inferior alveolar nerve that its extraction might expose patients to the risk of post-operative neuro-sensitive alterations of the skin and the mucosa of the homolateral lower lip and chin. Thus, the injury of the inferior alveolar nerve may represent a serious, though infrequent, neurologic complication in the surgery of the third molars rendering necessary a careful pre-operative evaluation of their anatomical relationship with the inferior alveolar nerve by means of radiographic imaging techniques. This contribution presents two case reports showing positive radiographic signs, which are the hallmarks of a possible close relationship between the inferior alveolar nerve and the third molars. We aim at better defining the relationship between third molars and the mandibular canal using Dental CT Scan, DICOM image acquisition and 3D reconstruction with a dedicated software. By our study we deduce that 3D images are not indispensable, but they can provide a very agreeable assistance in the most complicated cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-dose (123)I-metaiodobenzylguanidine diagnostic scan is inferior to (131)I-metaiodobenzylguanidine posttreatment scan in detection of malignant pheochromocytoma and paraganglioma.

OBJECTIVE We assessed the lesion detectability of low-dose diagnostic (123)I-metaiodobenzylguanidine (MIBG) whole-body scans obtained at 6 and 24 h compared with posttreatment (131)I-MIBG whole-body scans in malignant pheochromocytoma and paraganglioma. METHODS Scintigrams obtained in 15 patients with malignant pheochromocytoma and paraganglioma were retrospectively analyzed. Diagnostic scans...

متن کامل

Comparison of diagnostic value of I-123 MIBG and high-dose I-131 MIBG scintigraphy including incremental value of SPECT/CT over planar image in patients with malignant pheochromocytoma/paraganglioma and neuroblastoma.

PURPOSE to compare lesion detectability of I-123 MIBG scintigraphy with that of high-dose I-131 MIBG and to evaluate incremental benefit of SPECT/CT over planar image for the detection and localization of the lesions in patients with I-131 MIBG therapy for malignant pheochromocytoma/paraganglioma and neuroblastoma. MATERIALS AND METHODS we retrospectively investigated 16 patients with maligna...

متن کامل

Preliminary Characterization Tests of Detectors of on-Line Monitor Systems of the Italian National Center of Oncological Hadron-Therapy (CNAO)

Introduction Hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. The Italian National Center of Oncological Hadron-therapy (CNAO) has been realized as the first facility in Italy to treat very difficult tumors with protons and Carbon ions. The on-line monitor system for CNAO has been developed by the Department of Physics of the Univers...

متن کامل

The usefulness of iodine-123 whole-body scans in evaluating thyroid carcinoma and metastases.

OBJECTIVE It is recognized that diagnostic doses of (131)I larger than 3 mCi will cause some cell injury to the tissue in which it concentrates and reduce subsequent uptake of (131)I administered therapeutically. Iodine-123 has been suggested as an alternate radiopharmaceutical to perform whole-body scans since its primary emissions are photons with minimal particulate radiation and it does not...

متن کامل

A practical method of I-131 thyroid cancer therapy dose optimization using estimated effective renal clearance

In thyroid cancer patients with renal impairment or other complicating factors, it is important to maximize I-131 therapy efficacy while minimizing bone marrow and lung damage. We developed a web-based calculator based on a modified Benua and Leeper method to calculate the maximum I-131 dose to reduce the risk of these toxicities, based on the effective renal clearance of I-123 as measured from...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013