Pituitary adenomas: automatic static perimetry and Goldmann perimetry. A comparative study of 345 visual field charts.
نویسندگان
چکیده
In a series of 81 cases of pituitary adenoma 345 charts of visual field performed with static automatic perimetry (AP) on the Vision Monitor and Goldmann perimetry (GP) were compared. Generally both methods were equivalent in the detection of chiasmal compression. The charts were divided into two groups: (A) 208 charts and (B) 137 charts according to the number of isoptres investigated: two (V4, 112) or three (V4, 112, 12). In group A the AP was more often altered than the GP, and the difference was statistically significant (p less than 0.001). In group B the GP seemed more effective, but the number of questionable cases was greater and the difference was not statistically significant. When the most internal isoptre of GP was outside the central 30 degrees, AP was more often abnormal (29%) than GP (2.2%), and the difference was statistically significant (chi 2, p less than 0.001). Within the central 30 degrees the GP seemed more often to be altered (23% of cases) than the AP (19.4%), but one-third of the cases were questionable. Within the central 30 degrees both techniques gave identical results and there was no statistically significant difference. The discrepancies between both static and kinetic techniques are an argument for their complementary use.
منابع مشابه
A comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.
OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bil...
متن کاملA comparison of tangent screen, goldmann, and humphrey perimetry in the detection and localization of occipital lesions.
OBJECTIVE To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions. DESIGN Prospective consecutive comparative case series. PARTICIPANTS Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied. ...
متن کاملMechanisms mediating visual detection in static perimetry.
PURPOSE The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perim...
متن کاملComparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
PURPOSE To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. METHODS Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of ...
متن کاملDistance and near visual acuity, contrast sensitivity, and visual fields of 10-year-old children.
OBJECTIVE To measure monocular distance visual acuity, near visual acuity, contrast sensitivity, and visual field extent in full-term, 10-year-old children tested according to the protocol used to test 10-year-old preterm children in the Cryotherapy for Retinopathy of Prematurity study. SUBJECTS AND METHODS Subjects were 106 healthy, full-term children, 9.8 to 10.9 years of age, who had no oc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 75 4 شماره
صفحات -
تاریخ انتشار 1991