Potential repair of Escherichia coli DNA following exposure to UV radiation from both medium- and low-pressure UV sources used in drinking water treatment.

نویسندگان

  • J L Zimmer
  • R M Slawson
چکیده

The increased use of UV radiation as a drinking water treatment technology has instigated studies of the repair potential of microorganisms following treatment. This study challenged the repair potential of an optimally grown nonpathogenic laboratory strain of Escherichia coli after UV radiation from low- and medium-pressure lamps. Samples were irradiated with doses of 5, 8, and 10 mJ/cm(2) from a low-pressure lamp and 3, 5, 8, and 10 mJ/cm(2) from a medium-pressure UV lamp housed in a bench-scale collimated beam apparatus. Following irradiation, samples were incubated at 37 degrees C under photoreactivating light or in the dark. Sample aliquots were analyzed for up to 4 h following incubation using a standard plate count. Results of this study showed that E. coli underwent photorepair following exposure to the low-pressure UV source, but no repair was detectable following exposure to the medium-pressure UV source at the initial doses examined. Minimal repair was eventually observed upon medium-pressure UV lamp exposure when doses were lowered to 3 mJ/cm(2). This study clearly indicates differences in repair potential under laboratory conditions between irradiation from low-pressure and medium-pressure UV sources of the type used in water treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of DNA repair and survival of Escherichia coli O157:H7 following exposure to both low- and medium-pressure UV irradiation.

DNA repair and survival of pathogenic E. coli O157:H7 was investigated following exposure to ultraviolet (UV) radiation from both low-pressure (LP) and medium-pressure (MP) lamps. This study included irradiation at UV doses used in drinking water treatment and lower doses indicative of potential treatment problems. Immediately following UV exposure, an average log inactivation of 4.5 or greater...

متن کامل

Photoreactivation of Escherichia coli after low- or medium-pressure UV disinfection determined by an endonuclease sensitive site assay.

Photoreactivation of Escherichia coli after inactivation by a low-pressure (LP) UV lamp (254 nm), by a medium-pressure (MP) UV lamp (220 to 580 nm), or by a filtered medium-pressure (MPF) UV lamp (300 to 580 nm) was investigated. An endonuclease sensitive site (ESS) assay was used to determine the number of UV-induced pyrimidine dimers in the genomic DNA of E. coli, while a conventional cultiva...

متن کامل

Photocatalytic Removal of Escherichia Coli by ZnO Activated by Ultraviolet-C Light from Aqueous Solution

Abstract: Background and objectives: There is a great interest in photocatalytic oxidation of contaminants, using ZnO, in recent years. The main objective of this research was to study photocatalytic disinfection of E. coli bacteria as water microbial pollution index, using nano particles of ZnO and a UV lamp in a batch reactor. Material and Methods: In this study, the contaminated water sample...

متن کامل

Low-pressure UV inactivation and DNA repair potential of Cryptosporidium parvum oocysts.

Because Cryptosporidium parvum oocysts are very resistant to conventional water treatment processes, including chemical disinfection, we determined the kinetics and extent of their inactivation by monochromatic, low-pressure (LP), mercury vapor lamp UV radiation and their subsequent potential for DNA repair of UV damage. A UV collimated-beam apparatus was used to expose suspensions of purified ...

متن کامل

Inactivation of human adenovirus by sequential disinfection with an alternative UV technology and free chlorine.

There has been growing concern over human exposure to adenoviruses through drinking water due to the extreme resistance of human adenoviruses to the traditional UV technology (low-pressure (LP) UV). As an effort to develop an effective treatment strategy against human adenoviruses in drinking water, we determined the effectiveness of sequential disinfection with an alternative UV technology (me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 68 7  شماره 

صفحات  -

تاریخ انتشار 2002