A Case Demonstrating a Percutaneous Closure Using the Amplatzer Duct Occluder for Paravalvular Leakage after Tricuspid Valve Replacement

نویسندگان

  • Young Hee Heo
  • Soo-Jin Kim
  • Sang Yun Lee
  • Jae Suk Baek
چکیده

There has been a dramatic increase in the number and type of procedures performed in the field of cardiac intervention in the past decade. Percutaneous intervention is becoming an increasingly recognized modality for the management of prosthetic paravalvular leakages (PVLs) in severely symptomatic non-surgical candidates. Herein, we report our experience of percutaneous closure using the Amplatzer duct occluder for a PVL in a patient who underwent tricuspid valve replacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Treatment of Mitral Valve Periprosthetic Leakage. An Alternative to High-Risk Surgery?

Received February 6, 2008. Accepted for publication May 27, 2008. Periprosthetic mitral valve regurgitation due to paravalvular leakage is one of the complications of valve replacement surgery. We report a series of 8 patients with severe symptomatic periprosthetic mitral regurgitation in whom surgery could not be performed because of the high risk. All patients were assigned to percutaneous cl...

متن کامل

Percutaneous treatment of mitral valve periprosthetic leakage. An alternative to high-risk surgery?

Periprosthetic mitral valve regurgitation due to paravalvular leakage is one of the complications of valve replacement surgery. We report a series of eight patients with severe symptomatic periprosthetic mitral regurgitation in whom surgery could not be performed because of the high risk. All patients were assigned to percutaneous closure of periprosthetic mitral valve leaks using an Amplatzer ...

متن کامل

Percutaneous Closure of an Aortic Prosthetic Paravalvular Leak with Device in a Patient Presenting with Heart Failure

Paravalvular leaks (PVLs) are a well-recognized complication of prosthetic valve replacement. Perivalvular prosthetic regurgitation causes significant morbidity and is associated with high perioperative mortality if open surgical repair is required. PVLs manifest with symptoms of congestive heart failure, hemolysis, or in most cases, the combination of both. In recent years, the development of ...

متن کامل

Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with...

متن کامل

Percutaneous closure of mitral paravalvular leak.

Paravalvular leak (PVL) is a complication observed in patients after prosthetic valve replacement. The incidence of PVL is estimated as 2-3%. The cause of PVL may be paravalvular infection, suture continuity disruption, damage of tissues around the annulus or limitation of disc mobility by thrombus or vegetation. The preferable method of treatment of PVL is surgery. Recently, percutaneous closu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2013