Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

نویسندگان

  • Arndt Schimmelmann
  • Andrea Albertino
  • Peter E Sauer
  • Haiping Qi
  • Roland Molinie
  • François Mesnard
چکیده

Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different delta15N values. Comparative delta13C and delta15N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vivo Isotopic Labeling of Symbiotic Bacteria Involved in Cellulose Degradation and Nitrogen Recycling within the Gut of the Forest Cockchafer (Melolontha hippocastani)

The guts of insects harbor symbiotic bacterial communities. However, due to their complexity, it is challenging to relate a specific symbiotic phylotype to its corresponding function. In the present study, we focused on the forest cockchafer (Melolontha hippocastani), a phytophagous insect with a dual life cycle, consisting of a root-feeding larval stage and a leaf-feeding adult stage. By combi...

متن کامل

Compound-specific isotope analysis

The isotopic composition, e.g. 14C/12C, 13C/12C, 2H/1H, 15N/14N and 18O/16O, of matter elements is heterogeneous. It is ruled by physical, chemical and biological mechanisms. Isotopes thus be enable to follow the fate of mineral and organic compounds during biogeochemical transformations. The determination of the isotopic composition of organic substances occurring at trace level into very comp...

متن کامل

On-line Quantitative Determination of 2H/1H Isotope Ratios in Organic and Water Samples Using an Elemental Analyser Coupled to an Isotope Ratio Mass Spectrometer

A rapid continuous-Ñow technique for the quantitative determination of hydrogen isotope ratios in organic materials and water, at natural abundance levels, is described. Samples are pyrolysed in a helium stream at 1080 ÄC over an inert form of carbon. Hydrogen is separated from the other pyrolysis gases by gas chromatography and enters the ion source of the isotope ratio mass spectrometer (IRMS...

متن کامل

Isotopic fractionation of carbon and nitrogen during the illicit processing of cocaine and heroin in South America.

The forensic application of stable isotope analysis to cocaine and heroin for geolocation of exhibits must take into account the possible enrichment and/or depletion of 13C and 15N during the illicit manufacturing process. Continuous-flow elemental analysis-isotope ratio mass spectrometry was utilized to measure changes in the stable isotope ratios of carbon and nitrogen for both cocaine (N = 9...

متن کامل

Measure of carbon and nitrogen stable isotope ratios in cultured cells.

We report the measurement of the natural isotope ratios of nitrogen and carbon in subcellular volumes of individual cells among a population of cultured cells using a multi-isotope imaging mass spectrometer (MIMS), [MIMS is the prototype of the NanoSIMS 50, Cameca, France.] We also measured the nitrogen and carbon isotope ratio in cells after they had been cultured in media enriched with the am...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 23 22  شماره 

صفحات  -

تاریخ انتشار 2009