Nonlinear frequency compression: effects on sound quality ratings of speech and music.

نویسندگان

  • Vijay Parsa
  • Susan Scollie
  • Danielle Glista
  • Andreas Seelisch
چکیده

Frequency lowering technologies offer an alternative amplification solution for severe to profound high frequency hearing losses. While frequency lowering technologies may improve audibility of high frequency sounds, the very nature of this processing can affect the perceived sound quality. This article reports the results from two studies that investigated the impact of a nonlinear frequency compression (NFC) algorithm on perceived sound quality. In the first study, the cutoff frequency and compression ratio parameters of the NFC algorithm were varied, and their effect on the speech quality was measured subjectively with 12 normal hearing adults, 12 normal hearing children, 13 hearing impaired adults, and 9 hearing impaired children. In the second study, 12 normal hearing and 8 hearing impaired adult listeners rated the quality of speech in quiet, speech in noise, and music after processing with a different set of NFC parameters. Results showed that the cutoff frequency parameter had more impact on sound quality ratings than the compression ratio, and that the hearing impaired adults were more tolerant to increased frequency compression than normal hearing adults. No statistically significant differences were found in the sound quality ratings of speech-in-noise and music stimuli processed through various NFC settings by hearing impaired listeners. These findings suggest that there may be an acceptable range of NFC settings for hearing impaired individuals where sound quality is not adversely affected. These results may assist an Audiologist in clinical NFC hearing aid fittings for achieving a balance between high frequency audibility and sound quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Speech and music quality ratings for linear and nonlinear hearing aid circuitry.

This study evaluated quality ratings for speech and music stimuli processed using peak clipping (PC), compression limiting (CL), and wide-dynamic range compression (WDRC) hearing aid circuitry. Eighteen listeners with mild-to-moderate hearing loss were binaurally fitted with behind-the-ear (BTE) hearing aids and instructed to rate the quality of speech under various conditions in quiet and nois...

متن کامل

Quality ratings of frequency-compressed speech by participants with extensive high-frequency dead regions in the cochlea

OBJECTIVE The objective was to assess the degradation of speech sound quality produced by frequency compression for listeners with extensive high-frequency dead regions (DRs). DESIGN Quality ratings were obtained using values of the starting frequency (Sf) of the frequency compression both below and above the estimated edge frequency, fe, of each DR. Thus, the value of Sf often fell below the...

متن کامل

Harmonic Frequency Lowering

A novel algorithm for frequency lowering in music was developed and experimentally tested in hearing-impaired listeners. Harmonic frequency lowering (HFL) combines frequency transposition and frequency compression to preserve the harmonic content of music stimuli. Listeners were asked to make judgments regarding detail and sound quality in music stimuli. Stimuli were presented under different s...

متن کامل

Effects of noise, nonlinear processing, and linear filtering on perceived music quality.

OBJECTIVE The purpose of this study was to determine the relative impact of different forms of hearing aid signal processing on quality ratings of music. DESIGN Music quality was assessed using a rating scale for three types of music: orchestral classical music, jazz instrumental, and a female vocalist. The music stimuli were subjected to a wide range of simulated hearing aid processing condi...

متن کامل

Assessment of sound quality perception in cochlear implant users during music listening.

BACKGROUND Although cochlear implant (CI) users frequently report deterioration of sound quality when listening to music, few methods exist to quantify these subjective claims. OBJECTIVE 1) To design a novel research method for quantifying sound quality perception in CI users during music listening; 2) To validate this method by assessing one attribute of music perception, bass frequency perc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Trends in amplification

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2013