Ultrasound-Guided Needle Technique Accuracy
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES Ultrasound-guided regional anesthesia facilitates an approach to sensitive targets such as nerve clusters without contact or inadvertent puncture. We compared accuracy of needle placement with a novel passive magnetic ultrasound needle guidance technology (NGT) versus conventional ultrasound (CU) with echogenic needles. METHODS Sixteen anesthesiologists and 19 residents performed a series of 16 needle insertion tasks each, 8 using NGT (n = 280) and 8 using CU (n = 280), in high-fidelity porcine phantoms. Tasks were stratified based on aiming to contact (target-contact) or place in close proximity with (target-proximity) targets, needle gauge (no. 18/no. 22), and in-plane (IP) or out-of-plane (OOP) approach. Distance to the target, task completion by aim, number of passes, and number of tasks completed on the first pass were reported. RESULTS Needle guidance technology significantly improved distance, task completion, number of passes, and completion on the first pass compared with CU for both IP and OOP approaches (P ≤ 0.001). Average NGT distance to target was lower by 57.1% overall (n = 560, 1.5 ± 2.4 vs 3.5 ± 3.7 mm), 38.5% IP (n = 140, 1.6 ± 2.6 vs 2.6 ± 2.8 mm), and 68.2% OOP (n = 140, 1.4 ± 2.2 vs 4.4 ± 4.3 mm) (all P ≤ 0.01). Subgroup analyses revealed accuracy gains were largest among target-proximity tasks performed by residents and for OOP approaches. Needle guidance technology improved first-pass completion from 214 (76.4%) per 280 to 249 (88.9%) per 280, a significant improvement of 16.4% (P = 0.001). CONCLUSIONS Passive magnetic NGT can improve accuracy of needle procedures, particularly among OOP procedures requiring close approach to sensitive targets, such as nerve blocks in anesthesiology practice.
منابع مشابه
The Effects of Ultrasound-Guided Dry Needling on Patients With Myofascial Pain Syndrome: A Review Study
Objectives: Dry Needling (DN) is a novel and effective intervention for patients with Myofascial Pain Syndrome (MPS). Some characteristics, such as needle penetration depth, needle insertion into the target muscle, and trigger points must be identified in this intervention. The Ultrasound (US)-guided DN is a technique that involves needle insertion at the site of injury and the simulation of ti...
متن کاملAccuracy of Needle Placement in Cadavers: Non-Guided Versus Ultrasound-Guided
OBJECTIVE To compare the accuracy rates of non-guided vs. ultrasound-guided needle placement in four lower limb muscles (tibialis posterior, peroneus longus, and short and long heads of the biceps femoris). METHODS Two electromyographers examined the four muscles in each of eight lower limbs from four fresh frozen cadavers. Each electromyographer injected an assigned dye into each targeted mu...
متن کاملImpact of sedation technique on the diagnostic accuracy of endobronchial ultrasound-guided transbronchial needle aspiration
BACKGROUND AND OBJECTIVES There is a paucity of data concerning the impact of the sedation technique used for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) on diagnostic accuracy. The aim of this retrospective study was to compare the diagnostic accuracy of EBUS-TBNA in deep and moderate sedations, and to investigate other possible determinants of diagnostic accur...
متن کاملPerformance Accuracy of Hand-on-needle versus Hand-on-syringe Technique for Ultrasound-guided Regional Anesthesia Simulation for Emergency Medicine Residents
INTRODUCTION Ultrasound-guided nerve blocks (UGNB) are increasingly used in emergency care. The hand-on-syringe (HS) needle technique is ideally suited to the emergency department setting because it allows a single operator to perform the block without assistance. The HS technique is assumed to provide less exact needle control than the alternative two-operator hand-on-needle (HN) technique; ho...
متن کاملModified Ultrafast Papanicolaou Stain in Ultrasound Guided FNAC of Intra-abdominal Lesions
Background & Objective: Modified Ultra-fast Papanicolaou (MUFP) stain has been developed from Papanicolaou stain (PAP) with the...
متن کاملNeedle versus Forceps Technique in Ultrasound-Guided Synovial Biopsy of the Knee Joint
Objectives: Ultrasound-guided synovial biopsy is increasingly applied in rheumatology. Usually forcepsor needle-based techniques are used. So far there has been no direct comparison of different devices regarding their suitability in high resolution musculoskeletal ultrasound (hrMSUS)-guided synovial biopsy. Methods: A core needle biopsy (Quickcore, Cook Medical, Bloomington, IN, USA), an anter...
متن کامل