Quantitative measurement of pseudoexfoliation in the anterior segment of the eye performed in visible light

نویسندگان

  • Robert Koprowski
  • Zygmunt Wróbel
  • Anna Nowinska
  • Edward Wylegala
چکیده

INTRODUCTION Pseudoexfoliation syndrome (PEX) is a systemic disease involving the accumulation of pathological material deposits in the tissues of the anterior segment of the eye. The problem of modern ophthalmology is a quantitative assessment of the severity of PEX in the diagnosis and evaluation of the treatment progress in patients. MATERIAL AND METHOD For the purposes of this study, 52 images of the anterior segment of the eye with the resolution of M × N = 1280 × 960 pixels were obtained in jpg format using the slit lamp CSO 450-SL. The patients were aged 50-80 and were recruited from Poland. All patients who participated in the study provided written informed consent after explanation of the nature and possible consequences of the study. The image analysis method proposed by the authors contains the calculation of the direction field, setting a straight perpendicular line passing through each pixel of the edge of the pupil, the calculation of the intersection of straight lines in order to determine the central point of the pupil position, the detection of the contour of PEX and the outer border of the iris with the use of the polar coordinate system. All analyzed parameters were set automatically with one exception parameter chosen manually depending on the slit lamp type. RESULTS A fully automatic measurement of PEX was carried out with the proposed method. Quantitative results enable to perform reproducible tests independently of the research centre. Owing to the image analysis method proposed by the authors, it is possible to obtain results in no more than 1 second on the Intel Core 2 Quad CPU 2.50 GHz with a measurement error below 3%. Other known methods of image analysis and processing that are compared in this paper give results with a greater error (4-35%) which depends on the degree of magnification (×6, ×16, ×20) and are not fully automatic. CONCLUSIONS The methods of image analysis and processing enable a quantitative, repeatable and automatic measurement of the severity and progress of PEX syndrome. They support medical diagnosis and automatic archiving of results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudoexfoliation Syndrome in Diabetic Patients

OBJECTIVE: Pseudoexfoliation syndrome (PEX) leads to some problems in the eye surgery specially cataract surgery. As the prevalence of eye problems is high in diabetic patients, we meant to assess the prevalence of PEX in diabetic patients. MATERIALS AND METHODS: In this cross-sectional study, 400 type 2 diabetic patients aged 50 or above who referred to Yazd Diabetes Research Center were sele...

متن کامل

Evaluation of Bone Changes in Patients with Pseudoexfoliation Syndrome

Purpose: To evaluate the association of osteoporosis and pseudoexfoliation syndrome. Methods: This case-control observational study was conducted on patients admitted to Baghaee Poor eye clinic of Shahid Sadoughi Hospital, Yazd, in 2015. The case group included 35 patients diagnosed with pseudoexfoliation syndrome and the control group included 35 patients with no evidence of pseudoexfoliation ...

متن کامل

Pseudoexfoliation syndrome in various ethnic population of Nepal.

Pseudoexfoliation syndrome is an ocular condition characterized by a distinctive deposition of fibrillar material in the anterior segment of the eye. Pseudoexfoliation syndrome is frequently associated with glaucoma. Though it is seen in all the population, prevalence varies considerably in different races. A hospital based study done in Nepal by our group showed that Gurung population is frequ...

متن کامل

Fluorescein angiography and fluorophotometry of the iris in pseudoexfoliation of the lens capsule.

Fluorescein iris angiography and fluorophotometry were performed on a series of 9 patients with bilateral and 11 with unilateral pseudoexfoliation, 12 bilateral aphakes with pseudoexfoliation, and 7 unilateral aphakes with bilateral pseudoexfoliation. Angiography showed a loss of radial iris vessels, a heavy leak of fluorescein from the pupil margin, progressive neovascularisation of the outer ...

متن کامل

Pseudoexfoliation Syndrome and Sensorineural Hearing Loss

Introduction: Pseudoexfoliation syndrome (PXS) occurs due to the deposition of extracellular fibrillar materials on the anterior chamber of the eye. This syndrome has been considered to be part of a systemic disease with the potential involvement of the inner ear called sensoroneural hearing loss (SNHL).  In this study, we aimed on evaluating SNHL within PXS patients in Iran to compare them wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2013