Longitudinal evaluation of compressor/nebulizer performance.

نویسندگان

  • Samah Awad
  • David K Williams
  • Ariel Berlinski
چکیده

BACKGROUND Inhaled medications are the mainstay of treatment for maintenance of lung health in patients with cystic fibrosis (CF). Compressor/nebulizer units are used an average of 100-120 min/d by patients with CF. Each compressor/nebulizer has unique flow/pressure characteristics that affect particle size distribution and drug output rate. Few data are available regarding longitudinal performance of compressor/nebulizers. We hypothesized that their use over a 24-wk period under conditions similar to those of patients with CF would affect their performance. METHODS Four new units of compressor/reusable nebulizers from 3 brands (Pari Vios/Pari LC Plus, Pulmo-Aide 5650D/Viox, and Inspiration Elite/SideStream Plus) commonly used by patients with CF were tested. Compressor/nebulizers were operated for 1 h twice daily 5 d/wk for 24 wk. Compressor flow/pressure characteristics were measured every 6 wk. Maximal flow was recorded without and with the nebulizer (MF and MF/NEB, respectively). Pressure was recorded at zero flow (MP) and at MF/NEB (P/NEB). Particle size distribution, inhaled mass (IM), and IM in respirable range were evaluated at baseline and every 12 wk. RESULTS Vios had statistically significant declines in MP and P/NEB at each measurement compared with baseline (45.8 and 32.6 psi for MP and 16.7 and 14.3 psi for P/NEB at wk 0 and 24, respectively, P < .05), but other compressors did not. MF and MF/NEB were stable over time but significantly varied among brands. Vios had the greatest slope of flow/pressure relationship (Vios > Pulmo-Aide > Inspiration Elite). Two Vios units stopped working at wk 11 and 24, respectively. All compressors maintained baseline IM, IM in respirable range, and aerosol characteristics. CONCLUSIONS Long-term use of compressor/nebulizers in a regimen similar to that of patients with CF affected their performance. Pari Vios was the most affected brand, with declines in MP and P/NEB and 2 units that stopped working. Measurement of MF and MF/NEB could help identify compressors that are likely to fail.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro delivery of budesonide from 30 jet nebulizer/compressor combinations using infant and child breathing patterns.

BACKGROUND An aerosol of budesonide inhalation suspension is delivered when used with various jet-nebulizer/compressor combinations. The constant introduction of new nebulizer/compressor combinations raises the question of whether the performance of these match the performance of existing devices. The aim of this study was to determine in vitro the inhaled mass and aerosol characteristics of bu...

متن کامل

Comparison of twenty three nebulizer/compressor combinations for domiciliary use.

We have assessed the physical and dynamic characteristics of 23 home jet nebulizer/compressor combinations currently available in the UK and Europe. The combinations were evaluated in terms of pressure-flow characteristics, aerosol mass distribution, volume output, electrical costs, and sound level. In addition, we determined the effect of nebulizer fill volume on aerosol mass distribution and ...

متن کامل

Extending the Performance of an Existing Breath-Actuated Nebulizer for Domiciliary Use: Initial Data

The AeroEclipse® BAN (Trudell Medical International (TMI), London, Canada) was initially developed for use in the hospital environment, optimized for medication delivery using air or oxygen supplied at 50 psig pressure (2, 3). This article describes initial laboratory data with a version (AeroEclipse-XL®) optimized for operation by either table-top (OmbraTM table-top compressor, TMI, 230V AC ve...

متن کامل

Characterization of a human powered nebulizer compressor for resource poor settings

BACKGROUND Respiratory disease accounts for three of the ten leading causes of death worldwide. Many of these diseases can be treated and diagnosed using a nebulizer. Nebulizers can also be used to safely and efficiently deliver vaccines. Unfortunately, commercially available nebulizers are not designed for use in regions of the world where lung disease is most prevalent: they are electricity-d...

متن کامل

Blow-by as potential therapy for uncooperative children: an in-vitro study.

BACKGROUND Blow-by, a common form of nebulizer therapy, in which the device is held away from a child's face, has been dismissed as ineffective because studies have demonstrated incremental aerosol drop-off with increasing distances from the face. Many of these studies do not take into account differences among nebulizer systems. Using common, commercially available nebulizer systems, we define...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 59 7  شماره 

صفحات  -

تاریخ انتشار 2014