Strength estimation of a moving 125Iodine source during implantation in brachytherapy: application to linked sources

نویسندگان

  • Kenichi Tanaka
  • Satoru Endo
  • Kunihiko Tateoka
  • Osamu Asanuma
  • Masakazu Hori
  • Masaru Takagi
  • Gerard Bengua
  • Ken-ichi Kamo
  • Kaori Sato
  • Hiromitsu Takeda
  • Masato Hareyama
  • Koh-ichi Sakata
  • Jun Takada
چکیده

This study sought to demonstrate the feasibility of estimating the source strength during implantation in brachytherapy. The requirement for measuring the strengths of the linked sources was investigated. The utilized sources were (125)I with air kerma strengths of 8.38-8.63 U (μGy m(2) h(-1)). Measurements were performed with a plastic scintillator (80 mm × 50 mm × 20 mm in thickness). For a source-to-source distance of 10.5 mm and at source speeds of up to 200 mm s(-1), a counting time of 10 ms and a detector-to-needle distance of 5 mm were found to be the appropriate measurement conditions. The combined standard uncertainty (CSU) with the coverage factor of 1 (k = 1) was ∼15% when using a grid to decrease the interference by the neighboring sources. Without the grid, the CSU (k = 1) was ∼5%, and an 8% overestimation due to the neighboring sources was found to potentially cause additional uncertainty. In order to improve the accuracy in estimating source strength, it is recommended that the measurment conditions should be optimized by considering the tradeoff between the overestimation due to the neighboring sources and the intensity of the measured value, which influences the random error.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code

Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...

متن کامل

Measurement of the strength of iodine-125 seed moving at unknown speed during implantation in brachytherapy

The aim of this study is to demonstrate the feasibility of estimating the strength of the moving radiation source during patient implantation. The requirement for the counting time was investigated by comparing the results of the measurements for the static source with those for the source moving at 2, 5, 10 and 20 cm s(-1). The utilized source was (125)I with an air-kerma strength of 0.432 U (...

متن کامل

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective: The present study aims to modify source strength for different configurations of 125I and 103...

متن کامل

Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

متن کامل

Dosimetric characterization of a high dose rate 192I source for brachytherapy application using Monte Carlo simulation and benchmarking with thermoluminescent dosimetry

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014