Detection and quantitation of constriction of the fetal ductus arteriosus by Doppler echocardiography.

نویسندگان

  • J C Huhta
  • K J Moise
  • D J Fisher
  • D S Sharif
  • N Wasserstrum
  • C Martin
چکیده

Pulmonary hypertension may occur in the fetus in the presence of constriction of the ductus arteriosus. The feasibility of detection and quantitation of fetal ductal constriction by Doppler echocardiography was assessed in an animal preparation in which ductal constriction was created in the fetal lamb with a variable ligature causing varying degrees of fetal pulmonary hypertension (fetal pulmonary arterial systolic pressure 57 to 97 mm Hg and ductal gradient 9 to 42 mm Hg). Comparison of blinded, continuous-wave peak Doppler velocity (V) measurements of the ductal gradient with the modified Bernoulli assumption (gradient = 4V2) compared well with direct catheter measurements of instantaneous peak systolic gradient (r = .99, catheter = 0.95 X Doppler + 0.6), peak-to-peak gradient (r = .97), and mid-diastolic gradient (r = .85). Ductal constriction was characterized by an increase in the peak systolic and diastolic velocities. The normal human fetal ductus arteriosus blood flow velocity pattern was assessed by pulsed Doppler techniques in 25 normal human fetuses after 20 weeks gestation. The peak systolic flow velocity in the ductus arteriosus measured by image-directed pulsed Doppler echocardiography ranged from 50 to 141 cm/sec (mean 80 cm/sec) and increased with gestational age (r = .50). Diastolic velocity in the ductus arteriosus was consistently directed toward the descending aorta and ranged from 6 to 30 cm/sec. The ductal systolic velocities were the highest blood flow velocities in the fetal cardiovascular system. Application of these techniques to fetuses whose mothers were receiving indomethacin for treatment of premature labor at 30 to 31 weeks gestation confirmed this method to be sensitive for detection of fetal ductal constriction, which developed in three fetuses.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early Ductus Arteriosus Constriction: A Rare Case Presentation at 18 Weeks of Gestation

      The ductus arteriosus (DA) is a vital structure in fetal circulation, carrying about two thirds of the right ventricular (RV) output to the aorta. During fetal life, ductal patency is actively preserved by several different factors, and pathologic ductal constriction causes right-sided pressure overload of the heart, leading to RV failure. There have been many reports of ductal constricti...

متن کامل

DOPPLER ECHOCARDIOGRAPHY Detection and quantitation of constriction of the fetal ductus arteriosus by Doppler echocardiography

Pulmonary hypertension may occur in the fetus in the presence of constriction of the ductus arteriosus. The feasibility of detection and quantitation of fetal ductal constriction by Doppler echocardiography was assessed in an animal preparation in which ductal constriction was created in the fetal lamb with a variable ligature causing varying degrees of fetal pulmonary hypertension (fetal pulmo...

متن کامل

Comparison between M-Mode and Doppler echocardiography in diagnosis

Introduction: Patent ductus arteriosus (PDA) is the persistence of a normal fetal structure between left pulmonary artery and descending aorta. Persistence of this fetal structure beyond 10 days of life is considered abnormal. In this study we compared M-Mode and Doppler echocardiography in diagnosis of PDA in children at Aliasghar Hospital in Zahedan and Children hospital in Bandar Abbas for...

متن کامل

Noninvasive detection of pulmonary hypertension in patent ductus arteriosus by pulsed Doppler echocardiography.

Twenty-five patients with proven patent ductus arteriosus were examined by pulsed Doppler echocardiography (PDE) before invasive assessment. Ten patients had normal pulmonary artery pressures, and by PDE, pandiastolic ductal flow. Fifteen patients had elevation of mean pulmonary artery pressure, and by PDE, all had abbreviations of diastolic ductal flow. PDE correctly distinguished between pati...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 75 2  شماره 

صفحات  -

تاریخ انتشار 1987