Optimization of transmission-scan time for the FixER method: a MR-based PET attenuation correction with a weak fixed-position external radiation source
نویسندگان
چکیده
Molecular Imaging Center, National Institute of Radiological Sciences, Chiba, Japan In recent work, we proposed an MRI-based attenuation-coefficient (μ-value) estimation method that uses a weak fixed-position external radiation source to construct an attenuation map for PET/MRI. In this presentation we refer to this method as FixER, and perform a series of simulations to investigate the duration of the transmission scan required to accurately estimate μ-values. In FixER, a segmented anatomical image and transmission data acquired with a fixedposition radiation source are needed to obtain μ-values for each segment. FixER has the advantage that segmentation reduces the number of unknowns and tissue identification is unnecessary. First, the geometry of a whole body PET scanner was replicated in virtual space, and a T1-weighted head image was segmented into air, bone, brain, and soft tissues other than brain. Simulated PET transmission scans were performed with the fixed-position Na point source (1MBq) to obtain the intensities with (I) and without (I0) a digital phantom made from the segmented tissues. The blank scan to obtain I0 was performed for 180 secs. The path length of each tissue was then calculated from the segmented image and straight lines drawn from the source to each crystal. Finally, the μ-values of each tissue type were calculated based on Lambert-Beer’s law. All μ-values converged with increasing scan time. The μ-values for brain, bone and soft tissues were 0.101, 0.120 and 0.095 cm, respectively, for a 180 secs transmission scan. Using these values as points of reference, it was seen that a transmission scan of at least 46 secs is needed to estimate all μ-values within an accuracy of 3%. The optimal transmission-scan time for FixER was investigated for head imaging. In future work it is planned to also optimize the position and number of point sources for various body regions and numbers of segments.
منابع مشابه
Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملMR-based PET Attenuation Correction – Method and Validation
In combined PET/MR, the high soft tissue contrast of Magnetic Resonance Imaging (MRI) and the functional information of Positron Emission Tomography (PET) are combined in one machine. Although this combination still poses many technological challenges, recent progress [1] indicates that it is only a matter of time before PET/MR machines enter the market. On the software side, attenuation correc...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملNew approach for attenuation correction in SPECT images, using linear optimization
Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...
متن کاملImprovement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.
UNLABELLED Quantitative PET imaging relies on accurate attenuation correction. Recently, there has been growing interest in combining state-of-the-art PET systems with MR imaging in a sequential or fully integrated setup. As CT becomes unavailable for these systems, an alternative approach to the CT-based reconstruction of attenuation coefficients (μ values) at 511 keV must be found. Deriving μ...
متن کامل