Air-conditioning vs. presence of pathogenic fungi in hospital operating theatre environment.
نویسندگان
چکیده
Infections related to modern surgical procedures present a difficult problem for contemporary medicine. Infections acquired during surgery represent a risk factor related to therapeutical interventions. Eradication of microorganisms from hospital operating theatre environment may contribute to reduction of infections as the laminar flow air-conditioning considerably reduces the number of microorganisms in the hospital environment. The objective of the study was to evaluate the occurrence of fungi in air-conditioned operating theatre rooms. The study was carried out in one of the hospitals in Krak6w during December 2009. Indoor air samples and imprints from the walls were collected from five operating theatre rooms. A total of fifty indoor air samples were collected with a MAS-100 device, and twenty five imprints from the walls were collected using a Count Tact method. Fungal growth was observed in 48 air samples; the average numbers of fungi were within the range of 5-100 c.f.u. in one cubic metre of the air. Fungi were detected only in four samples of the wall imprints; the number of fungi was 0.01 c.f.u. per one square centimetre of the surface. The mould genus Aspergillus was most frequently isolated, and the species A. fumigatus and A. versicolor were the dominating ones. To ensure microbiological cleanness of hospital operating theatre, the air-conditioning system should be properly maintained. Domination of the Aspergillus fungi in indoor air as well as increase in the number of moulds in the samples taken in evenings (p < 0.05) may suggest that the room decontamination procedures were neglected.
منابع مشابه
Experimental Investigation of Flow Regimes in An Operating Theatre of 1200-Beds Teaching Hospital
Optimum design of air condition in surgical operating theatres requires more careful and refined control of flow and temperature characteristics to achieve sterile and comfort conditions. The present work is devoted to analyze the performance of HVAC system design in practical operating theatre in 1200-beds of Egyptian modern teaching hospital. The present experimental program comprises field m...
متن کاملT13-O-15: Air conditioning components THE USE OF HEAT RECOVERY DEVICES FOR REDUCING ENERGY CONSUMPTION OF TREATING VENTILATION AIR IN A TROPICAL OPERATING THEATRE
In the operating theatre, where exhausted air is not permitted to be re-circulated, maintaining the conditions could be tedious on the HVAC systems and found to be energy inefficient. This research will look into the potential energy savings using heat recovery devices in treating the ventilation air, without compromising the occupants’ thermal comfort and health in the conditioned space. For t...
متن کاملDoes the air condition system in busses spread allergic fungi into driver space?
The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 b...
متن کاملOperating theatre quality and prevention of surgical site infections
Surgical site infections (SSI) account for 14% to 17% of all hospital-acquired infections and 38% of nosocomial infections in surgical patients. SSI remain a substantial cause of morbidity and death, possibly because of the larger numbers of elderly surgical patients or those with a variety of chronic and immunocompromising conditions, and emergence of antibiotic-resistant microorganisms. Facto...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Wiadomosci parazytologiczne
دوره 57 2 شماره
صفحات -
تاریخ انتشار 2011