Night glucose control with MD-Logic artificial pancreas in home setting: a single blind, randomized crossover trial-interim analysis.

نویسندگان

  • Revital Nimri
  • Ido Muller
  • Eran Atlas
  • Shahar Miller
  • Olga Kordonouri
  • Natasa Bratina
  • Christiana Tsioli
  • Magdalena A Stefanija
  • Thomas Danne
  • Tadej Battelino
  • Moshe Phillip
چکیده

BACKGROUND Artificial pancreas (AP) systems have shown an improvement in glucose control and a reduced risk of nocturnal hypoglycemia under controlled conditions but remain to be evaluated under daily-life conditions. OBJECTIVE To assess the feasibility, safety, and efficacy of the MD-Logic AP in controlling nocturnal glucose levels in the patient's home. METHODS Two-arm study, each covering four consecutive nights comparing the MD-Logic AP ('closed-loop' arm) with sensor-augmented pump therapy ('control' arm). Fifteen patients (mean age 19 ± 10.4 yr, A1c 7.5 ± 0.5% or 58 ± 5.9 mmol/mol, diabetes duration 9.9 ± 8.2 yr) were randomly assigned either to 'Group A' (first 'closed-loop', then 'control' arm) or to 'Group B' (vice versa). Investigators were masked to treatment intervention. Primary endpoints were the time spent with glucose levels below 70 mg/dL and the percentage of nights in which the mean overnight glucose levels were within 90-140 mg/dL. Endpoint analyses were based on unmodified sensor glucose readings of the four study nights. RESULTS Time of glucose levels spent below 70 mg/dL was significantly shorter on the closed-loop nights than on control nights, median and interquartile range 3.8 (0, 11.6) and 48.7 (0.6, 67.9) min, respectively; p = 0.0034. The percentage of individual nights in which mean overnight glucose level was within 90-140 mg/dL was 67 (33, 88), and 50 (25, 75), under closed-loop and control nights, respectively, with no statistical difference. Secondary endpoint analyses demonstrated significant improvements in hypoglycemia parameters. No serious adverse events were reported. CONCLUSION This interim analysis demonstrates the feasibility, safety, and efficiency of the MD-Logic AP system in home use, and demonstrates an improvement over sensor-augmented pump therapy. (ClinicalTrials.gov identifier NCT01726829).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home

AIMS To assess the performance and safety of an integrated bihormonal artificial pancreas system consisting of one wearable device and two wireless glucose sensor transmitters during short-term daily use at home. METHODS Adult patients with type 1 diabetes using an insulin pump were invited to enrol in this randomized crossover study. Treatment with the artificial pancreas started with a day ...

متن کامل

MD-Logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial.

OBJECTIVE We evaluated the effect of the MD-Logic system on overnight glycemic control at patients' homes. RESEARCH DESIGN AND METHODS Twenty-four patients (aged 12-43 years; average A1c 7.5 ± 0.8%, 58.1 ± 8.4 mmol/mol) were randomly assigned to participate in two overnight crossover periods, each including 6 weeks of consecutive nights: one under closed loop and the second under sensor-augme...

متن کامل

Psychological outcomes of evening and night closed‐loop insulin delivery under free living conditions in people with Type 1 diabetes: a 2‐month randomized crossover trial

AIM To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system. METHODS In a randomized crossover trial patient-related outcomes associated with an evening-and-night artificial pancreas and sensor-augmented pump therapy were compared. Both interve...

متن کامل

Reduced Worries of Hypoglycaemia, High Satisfaction, and Increased Perceived Ease of Use after Experiencing Four Nights of MD-Logic Artificial Pancreas at Home (DREAM4)

AIMS This study assesses the impact of using an AP-system at home on fear of hypoglycaemia. In addition, satisfaction and acceptance of the new technology are evaluated. METHODS In a multicentre, multinational study of 75 patients using the MD-Logic AP during four consecutive nights in home setting 59 of them (aged 10-54 years, 54% male, HbA1c 7.89 ± 0.69% [62.72 ± 7.51 mmol/mol], diabetes du...

متن کامل

Randomized Crossover Comparison of Personalized MPC and PID Control Algorithms for the Artificial Pancreas

OBJECTIVE To evaluate two widely used control algorithms for an artificial pancreas (AP) under nonideal but comparable clinical conditions. RESEARCH DESIGN AND METHODS After a pilot safety and feasibility study (n = 10), closed-loop control (CLC) was evaluated in a randomized, crossover trial of 20 additional adults with type 1 diabetes. Personalized model predictive control (MPC) and proport...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric diabetes

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2014