Physiologic noise regression, motion regression, and TOAST dynamic field correction in complex-valued fMRI time series

نویسندگان

  • Andrew D. Hahn
  • Daniel B. Rowe
چکیده

As more evidence is presented suggesting that the phase, as well as the magnitude, of functional MRI (fMRI) time series may contain important information and that there are theoretical drawbacks to modeling functional response in the magnitude alone, removing noise in the phase is becoming more important. Previous studies have shown that retrospective correction of noise from physiologic sources can remove significant phase variance and that dynamic main magnetic field correction and regression of estimated motion parameters also remove significant phase fluctuations. In this work, we investigate the performance of physiologic noise regression in a framework along with correction for dynamic main field fluctuations and motion regression. Our findings suggest that including physiologic regressors provides some benefit in terms of reduction in phase noise power, but it is small compared to the benefit of dynamic field corrections and use of estimated motion parameters as nuisance regressors. Additionally, we show that the use of all three techniques reduces phase variance substantially, removes undesirable spatial phase correlations and improves detection of the functional response in magnitude and phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving robustness and reliability of phase-sensitive fMRI analysis using temporal off-resonance alignment of single-echo timeseries (TOAST)

Echo Planar Imaging (EPI), often utilized in functional MRI (fMRI) experiments, is well known for its vulnerability to inconsistencies in the static magnetic field (B(0)). Correction for these field inhomogeneities usually involves measuring the magnetic field at a single time point, and using this static information to correct a series of images collected over the course of one or multiple exp...

متن کامل

Enhancing the utility of complex-valued functional magnetic resonance imaging detection of neurobiological processes through postacquisition estimation and correction of dynamic B(0) errors and motion.

Functional magnetic resonance imaging (fMRI) time series analysis is typically performed using only the magnitude portion of the data. The phase information remains unused largely due to its sensitivity to temporal variations in the magnetic field unrelated to the functional response of interest. These phase changes are commonly the result of physiologic processes such as breathing or motion ei...

متن کامل

Methodology for Robust Motion Correction of Complex-valued MRI Time Series

Introduction: In functional MRI (fMRI), the presence of subject motion during the acquisition of an image series can confound results. In general practice, only the magnitude portion of the images is used in the functional analysis [1], and thus correction for subject motion is required in only the magnitude images. However, statistical models for performing complex-valued fMRI analysis are ava...

متن کامل

EEG-assisted retrospective motion correction for fMRI: E-REMCOR

We propose a method for retrospective motion correction of fMRI data in simultaneous EEG-fMRI that employs the EEG array as a sensitive motion detector. EEG motion artifacts are used to generate motion regressors describing rotational head movements with millisecond temporal resolution. These regressors are utilized for slice-specific motion correction of unprocessed fMRI data. Performance of t...

متن کامل

Correction of the Low-Frequency Physiological Noise in the Resting State BOLD fMRI - Effect on the ICA Default-Mode Analysis at 1.5T

Introduction: In the studies of low-frequency resting state networks (RSN) the impact of aliased physiologic noise has been a persistent source of criticism and uncertainty in the interpretation of the results. More recently, lagged estimates of the low-frequency physiological noise fluctuations (respiratory (1) and cardiac (2)) have been shown to explain notable signal variance in the regressi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 59 3  شماره 

صفحات  -

تاریخ انتشار 2012