Intensity-modulated radiotherapy for hepatocellular carcinoma: dosimetric and clinical results
نویسندگان
چکیده
Since the introduction of 3-dimensional conformal radiotherapy (3DCRT), new radiotherapy techniques have expanded the indication of radiotherapy for the treatment of hepatocellular carcinoma (HCC), from the hitherto palliative to a now curative-intent purpose. Intensity-modulated radiotherapy (IMRT), currently the most advanced radiotherapy technique, is considered an attractive option for the treatment of HCC, and is more widely applied because it can deliver a higher dose to the tumor than 3DCRT while sparing surrounding normal organs. However, the advantages and potential disadvantages of IMRT for treating HCC have not been fully established. This article deals with three different IMRT techniques, including static IMRT and volumetric modulated arc therapy using conventional multileaf collimator (MLC) mounted linear accelerators, and helical IMRT using binary MLC mounted helical tomotherapy machine. We review dosimetric and clinical studies for these IMRT techniques for the treatment of HCC.
منابع مشابه
3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملDosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma
Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملComparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)
Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients. Materials and Methods: Co...
متن کامل