Evaluation of corneal changes after myopic LASIK using the Pentacam®
نویسندگان
چکیده
BACKGROUND In this study, we used a Pentacam® device to evaluate the corneal changes that occur after laser-assisted in situ keratomileusis (LASIK). METHODS Our study included 60 eyes of 32 patients. All patients were treated for myopia and myopic astigmatism using LASIK. The eyes were examined preoperatively and 3 months postoperatively using a Pentacam to assess corneal changes with regard to curvature, elevation, and asphericity of the cornea. RESULTS A statistically significant decrease in mean keratometric power of the anterior corneal surface (P = 0.001) compared with its pre-LASIK value was detected after 3 months, but there was no significant change in keratometric power of the posterior surface (P = 0.836). Asphericity (Q-value) of the anterior and posterior surfaces increased significantly after LASIK (P = 0.001). A significant forward bulge of the anterior corneal surface 4 mm and 7 mm from the central zone was detected 3 months post-LASIK (P = 0.001 for both), but there was no significant increase in posterior elevation at 4 mm and 7 mm from the center (P = 0.637 and P = 0.26, respectively). No cases of post-LASIK ectasia were detected. Correlation between different parameters of the corneal surface revealed an indirect relation between changes in pachymetry and anterior corneal elevation at 4 mm and 7 mm from the central zone (r = -0.27, P = 0.13, and r = -0.37, P = 0.04, respectively), and a direct proportion between changes in pachymetry and mean keratometric power of the anterior and posterior corneal surfaces (r = 0.7, P = 0.001 and r = 0.4, P = 0.028, respectively). CONCLUSION LASIK causes significant changes at the anterior corneal surface but the effect is subtle and insignificant at the posterior surface.
منابع مشابه
Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by Pentacam as A New Imaging Technique
Purpose: To compare changes in posterior corneal elevation, anterior chamber depth (ACD), anterior chamber volume (ACV) and corneal volume (CV) after laser in situ keratomileusis (LASIK ) and photorefractive keratectomy (PRK) for low to moderate myopia by pentacam imaging Methods: In this prospective comparative case series, 105 consecutive myopic eyes randomly scheduled for LASIK (n=59) or PRK...
متن کاملPosterior Corneal Curvature Assessment after Epi-LASIK for Myopia: Comparison of Orbscan II and Pentacam Imaging
PURPOSE To compare the changes in posterior corneal curvature using scanning slit topography (Orbscan II) and Scheimpflug imaging (Pentacam) before and after Epi-laser in situ keratomileusis (LASIK) for myopia. METHODS In a prospective observational case-series study, 20 myopic patients having undergone Epi-LASIK were examined serially with two different devices, Orbscan II and Pentacam, preo...
متن کاملMinor influence of myopic laser in situ keratomileusis on the posterior corneal surface.
PURPOSE To check whether myopic LASIK induces changes on the posterior corneal surface. METHODS A Scheimpflug system (Pentacam; Oculus, GmbH, Wetzlar, Germany) was used to measure preoperative and postoperative posterior corneal topography in 27 eyes (of 14 subjects) that had undergone standard myopic LASIK surgery (attempted corrections between -1.25 and -8.50 D) and on 18 nonoperated eyes (...
متن کاملChanges in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy.
PURPOSE To study the changes in posterior corneal elevation after laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) using Scheimpflug topography with the Pentacam anterior segment imaging system (Oculus, Inc.). SETTING Department of Ophthalmology, Albany Medical Center, and a private clinical practice, Albany, New York, USA. METHODS In this prospective study, 121 co...
متن کاملComparison of central corneal thickness measurements using Pentacam and ultrasonic pachymetry in post-LASIK eyes for myopia.
PURPOSE To compare central corneal thickness (CCT) measurements obtained using the Pentacam Scheimpflug system with those obtained using DGH ultrasound pachymetry (UP) in post-laser in situ keratomileusis (LASIK) eyes for myopia. METHODS In a prospective study, measurement agreement was assessed in 143 eyes of 72 post-LASIK patients using both the Pentacam and UP at the Eye Consultants Center...
متن کامل