Evaluation of three methods for hemoglobin measurement in a blood donor setting.

نویسندگان

  • J Rosenblit
  • C R Abreu
  • L N Szterling
  • J M Kutner
  • N Hamerschlak
  • P Frutuoso
  • T R Paiva
  • O C Ferreira
چکیده

CONTEXT The hemoglobin (Hb) level is the most-used parameter for screening blood donors for the presence of anemia, one of the most-used methods for measuring Hb levels is based on photometric detection of cyanmetahemoglobin, as an alternative to this technology, HemoCue has developed a photometric method based on the determination of azide metahemoglobin. OBJECTIVE To evaluate the performance of three methods for hemoglobin (Hb) determination in a blood bank setting. DESIGN Prospective study utilizing blood samples to compare methods for Hb determination. SETTING Hemotherapy Service of the Hospital Israelita Albert Einstein, a private institution in the tertiary health care system. SAMPLE Serial blood samples were collected from 259 individuals during the period from March to June 1996. MAIN MEASUREMENTS Test performances and their comparisons were assessed by the analysis of coefficients of variation (CV), linear regression and mean differences. RESULTS The CV for the three methods were: Coulter 0.68%, Cobas 0.82% and HemoCue 0.69%. There was no difference between the mean Hb determination for the three methods (p>0.05). The Coulter and Cobas methods showed the best agreement and the HemoCue method gave a lower Hb determination when compared to both the Coulter and Cobas methods. However, pairs of methods involving the HemoCue seem to have narrower limits of agreement (+/- 0.78 and +/- 1.02) than the Coulter and Cobas combination (+/- 1.13). CONCLUSION The three methods provide good agreement for hemoglobin determination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperbilirubinemia Following Exchange Transfusion with G-6-PD Deficient Donor Blood

Background: The incidence of glucose-6-phosphate dehydrogenase (G-6-PD) deficiency in Iran is estimated at 10-14.9%.  The donor blood in blood banks is not screened routinely for this enzyme deficiency and such blood may be used for neonatal exchange transfusion.Objective: To study the effect of G-6-PD deficient blood in neonatal exchange blood transfusion.Methods: In a prospective study, serum...

متن کامل

Evaluation of Hemoglobin Concentration of Cord, Capillary and Venous sampling in Neonates

Abstract Background Anemia is one of the most common abnormalities in pediatric medicine. Considerable differences are seen in the peripheral blood indices of infants in developing countries. The aim of this study was to determine and compared blood hemoglobin concentration in three sites of sampling in neonate. Materials and Methods 1600 term and preterm new infant in three sites of sampli...

متن کامل

The Iranian Blood Transfusion, Donor Safety Program: Effect of Long-term Plasmapheresis on Plasma Proteins

Background: Plasmapheresis is a well-recognised method for harvestingplasma.  It was introduced in the 1950s and is currently employed worldwide.  This method has been in use in Iran since 1979. Objective: To evaluate the efficacy of donor safety program used at the Iranian Blood Transfusion Organization. Methods: A comparison is made of the protein concentrations between the first-time and lon...

متن کامل

Iron stores in blood donors: A literature mini review

An increase in the frequency of blood donation among the donor population is liable to result in excessive iron loss and development of iron deficiency anemia. In the majority of blood banks, hemoglobin and/or hematocrit measurements are used as screening tests for the ability to donate blood even though iron stores may be depleted in donors with hemoglobin values above the arbitrarily defi...

متن کامل

Increasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method

Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sao Paulo medical journal = Revista paulista de medicina

دوره 117 3  شماره 

صفحات  -

تاریخ انتشار 1999