Radiation induced currents in MRI RF coils

نویسندگان

  • B Burke
  • B G Fallone
  • S Rathee
چکیده

The integration of medical linear accelerators (linac) with magnetic resonance imaging (MRI) systems is advancing the current state of image-guided radiotherapy. The MRI in these integrated units will provide real-time, accurate tumor locations for radiotherapy treatment, thus decreasing geometric margins around tumors and reducing normal tissue damage. In the real-time operation of these integrated systems, the radiofrequency (RF) coils of MRI will be irradiated with radiation pulses from the linac. The effect of pulsed radiation on MRI radio frequency (RF) coils is not known and must be studied. The instantaneous radiation induced current (RIC) in two different MRI RF coils were measured and presented. The frequency spectra of the induced currents were calculated. Some basic characterization of the RIC was also done: isolation of the RF coil component responsible for RIC, dependence of RIC on dose rate, and effect of wax buildup placed on coil on RIC. Both the time and frequency characteristics of the RIC were seen to vary with the MRI RF coil used. The copper windings of the RF coils were isolated as the main source of RIC. A linear dependence on dose rate was seen. The RIC was decreased with wax buildup, suggesting an electronic disequilibrium as the cause of RIC. This study shows a measurable RIC present in MRI RF coils. This unwanted current could be possibly detrimental to the signal to noise ratio in MRI and produce image artifacts. (Some figures in this article are in colour only in the electronic version)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Consideration of physiological response in numerical models of temperature during MRI of the human head.

PURPOSE To examine the thermal effects of the physiological response to heating during exposure to radiofrequency (RF) electromagnetic fields in magnetic resonance imaging (MRI) with a head-specific volume coil. MATERIALS AND METHODS Numerical methods were used to calculate the temperature elevation in MRI of the human head within volume coils from 64-400 MHz at different power levels both wi...

متن کامل

Eddy-Current-Compensated RF Pulse Design for Parallel Excitation

Introduction: High-performance RF coils and shielded Gradient coils [1] for high or ultra high field MRI often require the use of RF shields that are in close proximity to the imaged volume. These shields can sometimes generate Eddy-Currents that are not adequately compensated for using the pre-emphasis algorithm [2] of the scanner. K-space trajectory measurements [3] can be used to compensate ...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

The shielding of RF MRI coils using double-sided EMI shield

We present, here, a device for shielding the RF MRI coils to eliminate their undesired radiation, and to restore the natural resonant frequency f0 in the presence of a biological sample. It is presented for a planar surface RF MRI coil. Nonetheless, this approach is also valid for conformal coils as well. Introduction The influence of any biological sample on an RF MRI coil results in a shift o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010