Updated Uncertainty Analysis for a Flowmeter Calibration Process Part 1: Transfer Standards

نویسنده

  • Thomas Kegel
چکیده

A transfer standard for flowmeter calibration provides traceability to a primary standard. It is typically used for most commercial calibrations because it represents an economically attractive alternative to a primary system. A set of critical flow venturi (CFV) transfer standards have been maintained in calibration at CEESI for the past 35 years. The uncertainty in mass flowrate has been estimated to be ±0.5% at 95% level of confidence based on analysis of the components that contribute uncertainty. This paper presents analysis of historical data that supports a lower estimate of uncertainty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration and Standards in Flow Measurement

Calibration is defined as follows: ‘The set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system and the corresponding values realized by standards.’ It is important to recognize at the outset the definition of a ‘calibration’ and to note that the ‘comparison’ applies only to the condition...

متن کامل

The Characterization of a Piston Displacement-Type Flowmeter Calibration Facility and the Calibration and Use of Pulsed Output Type Flowmeters

Critical measurement performance of fluid flowmeters requires proper and quantified verification data. These data should be generated using calibration and traceability techniques established for these verification purposes. In these calibration techniques, the calibration facility should be well-characterized and its components and performance properly traced to pertinent higher standards. The...

متن کامل

Uncertainty in NIST Force Measurements

This paper focuses upon the uncertainty of force calibration measurements at the National Institute of Standards and Technology (NIST). The uncertainty of the realization of force for the national deadweight force standards at NIST is discussed, as well as the uncertainties associated with NIST's voltage-ratio measuring instruments and with the characteristics of transducers being calibrated. T...

متن کامل

Application of a New Method for the Automated Calibration of Very Low Gauge and Absolute Pressures in a Commercial Calibration Laboratory

Maintaining traceability for transfer standards in the range of 10 Pa to 5 kPa is critical to many calibration laboratories. However, standards with suitable uncertainty that can also be practically implemented in the typical laboratory have not been available. A new pressure standard based on piston-cylinder technology has been developed that provides the measurement uncertainty needed to supp...

متن کامل

Source Standards for the Radiometric Calibration of Astronomical Instruments in the VUV Spectral Range Traceable to the Primary Standard BESSY

On the basis of a high-current hollow-cathode discharge we have developed two transfer source standards suitable for the radiometric calibration of vacuum-ultraviolet (VUV) telescopes. The source standards are transportable and (in their current design) produce collimated beams of 5 mm (grazing-incidence region) and 2.5 mm, 5 mm, 10 mm and 15 mm (normal-incidence region) diameter. By irradiatin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001