Control of filtering bleb structure through tissue bioengineering: An animal model.

نویسندگان

  • Henry Shen-Lih Chen
  • Robert Ritch
  • Theodore Krupin
  • Wei-Cherng Hsu
چکیده

PURPOSE To devise a means of providing controlled resistance between the anterior chamber and the subconjunctival space after trabeculectomy by implantation of a biodegradable, porous collagen matrix. METHODS Matrices were implanted in the right eyes of 17 rabbits after trabeculectomy, while left eyes served as surgical controls. The scleral flap was sutured loosely, and the implant provided pressure on the scleral flap to reduce overfiltration. Trabeculectomy in the control eyes was performed with tight sutures using standard methodology. Intraocular pressure (IOP) was measured before surgery and on days 3, 7, 14, 21, and 28 after surgery. Masson trichrome and alpha-smooth muscle actin stains were used for histologic study of the filtering blebs. RESULTS The initial postoperative IOP reduction was approximately equal, at 14% to 16%, for both groups. In the implanted group, the IOP continued to decrease to 55% below baseline at day 28 as the implant gradually degraded. In the control group, IOP had returned to the preoperative level by day 21. Histologic examination with Masson trichrome and alpha-smooth muscle actin stains showed a prominent bleb in the implanted group compared with scar formation and limited bleb formation in the control group. CONCLUSIONS Implantation of a biodegradable, porous collagen matrix in the subconjunctival space offers the potential for a new means of avoiding early scar formation and maintaining long-term IOP control by creating a loosely structured filtering bleb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amniotic Membrane Transplantation for Exuberant Bleb Following Filtration Surgery

The use of antimetabolites in filtration surgery, cystic, large, leaking blebs often lead to complications. We report a case of glaucoma that received amniotic membrane transplantation for repairing the exuberant bleb. This female patient had a history of several eye surgeries, including a scleral buckle and cyclocryotherapy for one eye and the other received filtering surgery. The latter had b...

متن کامل

Evaluation of filtering bleb function by thermography.

AIM To determine whether thermography can be used to evaluate bleb function. METHODS The surface temperatures of filtering blebs from 39 eyes of 33 post-trabeculectomy patients were measured using thermography. We introduced a new parameter: the temperature decrease in the filtering bleb (TDB) where TDB = (mean temperature of the temporal and nasal bulbar conjunctiva)-(temperature of the filt...

متن کامل

Correlation between Tissue Characterization and Dynamic Expression of Matrix Metalloproteinase-2 and Its Tissue Inhibitor in Conjunctival Filtering Bleb of Rats

PURPOSE Using rat conjunctival bleb model, we correlated changes morphology and histology in the bleb with changes in MMP-2 and TIMP-2 levels. METHODS Filtering surgeries were performed on rats. Dynamic changes in morphology and histopathology were observed using HE staining. Expression of MMP-2 and TIMP-2 was determined by immunofluorescence microscopy and western blotting. RESULTS Well-el...

متن کامل

EXTENDED REPORT Filtering bleb function after clear cornea phacoemulsification: a prospective study

Aim: To evaluate the influence of clear cornea phacoemulsification on filtering bleb morphology, function, and intraocular pressure (IOP) in glaucomatous eyes with previously successful filtering surgery. Methods: The clinical course of 30 patients (30 eyes) who underwent clear cornea phacoemulsification after successful filtering glaucoma surgery was prospectively evaluated. Mean IOP and filte...

متن کامل

Power filtering method with controllable inductance for eliminating thyristor rectifier load harmonics

In this paper, we propose a Controlled Inductance Power Filter (CIPF) to solve power quality problems in industrial DC power supply systems. This method is based on the theory of magnetic potential equilibrium combined with active hybrid filter technology. Initially the system structure and filter wiring scheme are presented and the equivalent circuit is performed with the mathematical models o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 2006