Barely Alive Servers: Greener Datacenters Through Memory-Accessible, Low-Power States

نویسندگان

  • Vlasia Anagnostopoulou
  • Susmit Biswas
  • Heba Saadeldeen
  • Alan Savage
  • Ricardo Bianchini
  • Tao Yang
  • Diana Franklin
  • Frederic T. Chong
چکیده

Current resource provisioning schemes in Internet services leave servers less than 50% utilized almost all the time. At this level of utilization, the servers’ energy efficiency is substantially lower than at peak utilization. A solution to this problem could be dynamically consolidating workloads into fewer servers and turning others off. However, services typically resist doing so, because of high response times during re-activation in handling traffic spikes. Moreover, services often want the memory and/or storage of all servers to be readily available at all times. In this paper, we propose a family of barely-alive active low-power server states that facilitates both fast re-activation and access to memory while in a low-power state. We compare these states to previously proposed active and idle states. In particular, we investigate the impact of load bursts in each energy-saving scheme. We also evaluate the additional benefits of memory access under low-power states with a study of a search service using a cooperative main-memory cache. Finally, we further investigate our barely-alive states in two case studies: (1) a mixed system that combines a barely-alive state with the off state to maximize energy savings; and (2) a barely-alive system that facilitates hosting more than one service at the same time. We find that the barely-alive states can reduce service energy consumption by up to 38%, compared to an energy-oblivious system. These energy savings are consistent across a large parameter space. In the presence of two services, the barely-alive system can reduce energy consuption by 34% over a two-system deployment. Vlasia Anagnostopoulou⋆ (e-mail: [email protected]), Susmit Biswas⋆ (e-mail: [email protected]), Heba Saadeldeen⋆ (e-mail: [email protected]), Alan Savage⋆ (e-mail: [email protected]), Ricardo Bianchini† (e-mail: [email protected]), Tao Yang⋆ (e-mail: [email protected]), Diana Franklin⋆ (e-mail: [email protected]) and Frederic T. Chong⋆ (e-mail: [email protected]) ⋆University of California Santa Barbara, Santa Barbara, CA 93106 †Rutgers University, Piscataway, NJ 08854

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy Conservation in Datacenters through Cluster Memory Management and Barely-Alive Memory Servers

As a result of current resource provisioning schemes in Internet services, servers end up less than 50% utilized almost all the time. At this level of utilization, the servers’ energy efficiency is less than half their efficiency at peak utilization. A solution to this problem could be consolidating workloads into fewer servers and turning others off. However, services typically resist doing so...

متن کامل

A Barely Alive Memory Servers: Keeping Data Active in a Low-Power State

Current resource provisioning schemes in Internet services leave servers less than 50% utilized almost all the time. At this level of utilization, the servers’ energy efficiency is substantially lower than at peak utilization. A solution to this problem could be dynamically consolidating workloads into fewer servers and turning others off. However, services typically resist doing so, because of...

متن کامل

Resource Management by Virtual Machine Migration in Cloud Computing

Cloud computing is a quickly emerging field in computer science. It offers a wide variety of advantages over the traditional computing systems. Fast provisioning of resources, low upfront payment, minimal infrastructure management issues and so on. These enticing benefits offered by cloud computing has made it viable for many small organizations and keen individual developers as well. All of th...

متن کامل

A Performance Study of Big Data on Small Nodes

The continuous increase in volume, variety and velocity of Big Data exposes datacenter resource scaling to an energy utilization problem. Traditionally, datacenters employ x8664 (big) server nodes with power usage of tens to hundreds of Watts. But lately, low-power (small) systems originally developed for mobile devices have seen significant improvements in performance. These improvements could...

متن کامل

2013 Maurice Wilkes Award Given to Parthasarathy (Partha) Ranganathan

......Parthasarathy (Partha) Ranganathan received the 2013 Maurice Wilkes Award “for contributions to the design of power-efficient microblade servers and pioneering work in disaggregated system designs.” Partha has been a leading advocate for new system designs to improve energy efficiency and total cost of ownership (TCO) in large-scale datacenters. The technology inflection point of the last...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012