T1 mapping of the myocardium: Intra-individual assessment of the effect of field strength, cardiac cycle and variation by myocardial region
نویسندگان
چکیده
BACKGROUND Myocardial T1 relaxation time (T1 time) and extracellular volume fraction (ECV) are altered in the presence of myocardial fibrosis. The purpose of this study was to evaluate acquisition factors that may result in variation of measured T1 time and ECV including magnetic field strength, cardiac phase and myocardial region. METHODS 31 study subjects were enrolled and underwent one cardiovascular MR exam at 1.5 T and two exams at 3 T, each on separate days. A Modified Look-Locker Inversion Recovery (MOLLI) sequence was acquired before and 5, 10, 12, 20, 25 and 30 min after administration of 0.15 mmol/kg gadopentetate dimeglumine (Gd-DTPA; Magnevist) at 1.5 T (exam 1). For exam 2, MOLLI sequences were acquired at 3 T both during diastole and systole, before and after administration of Gd-DTPA (0.15 mmol/kg Magnevist).Exam 3 was identical to exam 2 except gadobenate dimeglumine was administered (Gd-BOPTA; 0.1 mmol/kg Multihance). T1 times were measured in myocardium and blood. ECV was calculated by (ΔR1myocardium/ΔR1blood)*(1-hematocrit). RESULTS Before gadolinium, T1 times of myocardium and blood were significantly greater at 3 T versus 1.5 T (28% and 31% greater, respectively, p < 0.001); after gadolinium, 3 T values remained greater than those at 1.5 T (14% and 12% greater for myocardium and blood at 3 T with Gd-DTPA, respectively, p < 0.0001 and 18% and 15% greater at 3 T with Gd-BOPTA, respectively, p < 0.0001). However, ECV did not vary significantly with field strength when using the same contrast agent at equimolar dose (p = 0.2). Myocardial T1 time was 1% shorter at systole compared to diastole pre-contrast and 2% shorter at diastole compared to systole post-contrast (p < 0.01). ECV values were greater during diastole compared to systole on average by 0.01 (p < 0.01 to p < 0.0001). ECV was significantly higher for the septum compared to the non-septal myocardium for all three exams (p < 0.0001-0.01) with mean absolute differences of 0.01, 0.004, and 0.07, respectively, for exams 1, 2 and 3. CONCLUSION ECV is similar at field strengths of 1.5 T and 3 T. Due to minor variations in T1 time and ECV during the cardiac cycle and in different myocardial regions, T1 measurements should be obtained at the same cardiac phase and myocardial region in order to obtain consistent results.
منابع مشابه
Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners
BACKGROUND Cardiovascular magnetic resonance (CMR) T1 mapping indices, such as T1 time and partition coefficient (λ), have shown potential to assess diffuse myocardial fibrosis. The purpose of this study was to investigate how scanner and field strength variation affect the accuracy and precision/reproducibility of T1 mapping indices. METHODS CMR studies were performed on two 1.5T and three 3...
متن کاملEffect of six weeks low intensity interval training on expression of atrial and brain natriuretic peptide genes following myocardial infarction in rat
Background: Myocardial infarction (MI) is the irreversible cell death caused by ischemia in parts of myocardium. Atrial and Brain natriuretic peptides (ANP and BNP) are known as strong markers of myocardial infarction. This study was aimed to evaluate the effect of six weeks low intensity interval training on ANP and BNP genes expression in rats following myocardial infarction. Materials and m...
متن کاملInfluence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method
BACKGROUND Myocardial T1-mapping methods such as MOLLI use SSFP readout and are prone to frequency-dependent error in T1-measurement. A significant error in T1 may result at relatively small off-resonance frequencies that are well within the region without banding artifacts. METHODS The sensitivity of T1-estimates based on the SSFP based MOLLI sequence to errors in center frequency are calcul...
متن کاملPrediction of long-term cardiac events by 123I-MIBG imaging after acute myocardial infarction and reperfusion therapy
Objective(s): In heart failure, the heart-to-mediastinum (H/M) ratio of the delayed image and washout rate (WR) are well-known as a powerful cardiac event predictors. H/M ratio quantifies the accumulation rate of MIBG in the myocardium and WR quantifies reduction of meta-iodobenzylguanidine (MIBG) accumulation in the heart from the early planar image to the delayed pla...
متن کاملTranslation of Methdology used in Human Myocardial Imaging to a Sheep Model of Acute Myocardial Infarction
Background: Pre-clinical investigation of stem cells for repairing damaged myocardium predominantly used rodents, however large animals have cardiac circulation closely resembling the human heart. The aim of this study was to evaluate whether SPECT/CT myocardial perfusion imaging (MPI) could be used for assessing sheep myocardium following an acute myocardial infarction (MI) and response to int...