Device Physics
نویسنده
چکیده
5 Equilibrium Carrier Statistics 7 5.1 Calculation of Fermi Level General Case . . . . . . . . . . . . . . . . . . . 7 5.2 Calculation of Fermi Level Special Analytical Cases . . . . . . . . . . . . . 10 5.2.1 CASE(A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5.2.2 CASE(A.1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5.2.3 CASE(B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5.2.4 CASE(C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 5.3 Doping and Temperature Dependence of Fermi Level . . . . . . . . . . . . . 12 5.4 Inhomogeneous Semiconductors . . . . . . . . . . . . . . . . . . . . . . . . . 13 5.4.1 Non-Uniform Doping and Quasi-Neutrality . . . . . . . . . . . . . . . 13 5.4.2 Abrupt pn Junction and Depletion Approximation . . . . . . . . . . . 14 5.4.3 Inhomogeneity in Band Edges . . . . . . . . . . . . . . . . . . . . . . 14
منابع مشابه
Development of A Head Docking Device for Linac-based Stereotactic Radiosurgery System to be Installed on Neptun 10 PC Linac
Introduction: Stereotactic radiosurgery is a technique for the treatment of intracranial lesions with highly collimated x-ray beam. Linac-based radiosurgery is currently performed by two techniques: couch or pedestal mounted. In the first technique, a device is required to affix patient's head to a couch and moreover to translate it accurately. Structure of suc...
متن کاملAnalysis of human pulse performance using the device of laser Doppler vibrometer
This article has no abstract.
متن کاملHiding an elephant into a matchbox with transformation optics
Based on transformation optics, we propose an illusion device that can make objects look much smaller and different than they actually are. In particular, the device has a capability to hide a large object (like an elephant) into a small one (like a matchbox). Compared to previous proposals for illusion devices, there is no requirement for negative refractive index or for spee...
متن کاملNew electrical device for field coincidence quality control test in linear accelerators
Testing of the coincidence of a linear accelerators X-ray field and the light field as a quality control test is often done in a subjective method, involving the manual marking of pieces of film and the visual inspection of the film after irradiation. The purpose of this study was to develop an objective method for performing this test, while also increasing the accuracy, precision and the spee...
متن کاملComparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملBreast dose in conventional and digital mamography
Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography fo...
متن کامل